5.10 o: Operator Related Settings

244

YASKAWA ELECTRIC SIEP YAIL1E 01A YASKAWA AC Drive L1000E Technical Manual

o2-06: Operation Selection when Digital Operator is Disconnected

Determines whether the drive will stop when the digital operator is removed in LOCAL mode or when b1-02 is set to 0.
When the operator is reconnected, the display will indicate that it was disconnected.

Setting 0: Continue operation

The operation is continued.

Setting 1: Trigger a fault

The operation is stopped and an “oPr” fault is triggered. The motor coasts to stop.

o3: Copy Function

These parameters control the Copy function of the digital operator. The Copy function stores parameter settings into the
memory of the digital operator to facilitate the transfer of those settings to other drives that are the same model, capacity,
and same control mode setting.

Refer to Copy Function Related Displays on page 301

for a description of errors and

displays.

o3-01 Copy Function Selection

Instructs the drive to Read, Write, or Verify parameter settings.

Setting 0: Copy Select (no function)
Setting 1: INV

OP READ

Copies all parameters from the drive to the digital operator.

Note: The copy protection for the digital operator is enabled by default. Set o3-02 to 1 to unlock copy protection.

Setting 2: OP

INV WRITE

Compares the parameters in the drive with the parameter settings saved on the digital operator for matches.

Setting 3: OP

INV VERIFY

Parameters in the drive are compared with the parameter settings saved on the digital operator to see if they match.

o3-02 Copy Allowed Selection

Allows and restricts the use of the Copy function.

Setting 0: Disabled
Setting 1: Enabled

No.

Parameter Name

Setting Range

Default

o2-06

Digital Operator Disconnection Operation

0 or 1

0

No.

Parameter Name

Setting Range

Default

o3-01

Copy Function Selection

0 to 3

0

No.

Parameter Name

Setting Range

Default

o3-02

Copy Allowed Selection

0 or 1

0