D: speed references, D1: speed reference, B.3 parameter table – Yaskawa L1000E AC Drive Technical Manual for CIMR-LE Models for Elevator Applications User Manual

Page 374

Advertising
background image

B.3 Parameter Table

374

YASKAWA ELECTRIC SIEP YAIL1E 01A YASKAWA AC Drive L1000E Technical Manual

d: Speed References

Speed Reference parameters are used to set the various speed reference values during operation.

d1: Speed Reference

C6-31

(77AH)

Carrier Frequency during Rescue
Operation

Sets the carrier frequency during Rescue Operation.
0: C6-03 setting
1: 2 kHz

Default: 0
Min: 0
Max: 1

173

<4> Default setting value varies by the drive model (o2-04).

No.(Addr.)

Name

Description

Setting

Page

d1-01

(280H)

Speed Reference 1

Sets the Speed reference for the drive when d1-18 is set to 0 or 3. Setting units are determined
by parameter o1-03.

Default: 0.00%

<6>

Min: 0.00%
Max: 100.00%

<6>

174

d1-02

(281H)

Speed Reference 2

d1-03

(282H)

Speed Reference 3

d1-04

(283H)

Speed Reference 4

d1-05

(284H)

Speed Reference 5

d1-06

(285H)

Speed Reference 6

d1-07

(286H)

Speed Reference 7

d1-08

(287H)

Speed Reference 8

d1-18

(2C0H)

Speed Reference Selection Mode

Sets the mode of speed reference selection by digital inputs.
0: Use multi-speed references (d1-01 to d1-08)
1: High speed reference has priority (d1-19 to d1-23, d1-26)
2: Leveling speed reference has priority (d1-19 to d1-23, d1-26)
3: Use multi-speed references d1-02 to d1-08, no speed selection stops the drive. Drive will stop
when all input terminals programmed for speed references (H1-…… = 3, 4, 5) are open.

Default: 0
Min: 0
Max: 3

174

d1-19

(2C1H)

Nominal Speed

Sets the nominal speed reference when d1-18 = 1 or 2.

Default: 100.00%

<6>

Min: 0.00%
Max: 100.00%

<6>

175

d1-20

(2C2H)

Intermediate Speed 1

Sets intermediate speed reference 1 when d1-18 = 1 or 2.

Default: 0.00%

<6>

Min: 0.00%
Max: 100.00%

<6>

175

d1-21

(2C3H)

Intermediate Speed 2

Sets intermediate speed reference 2 when d1-18 = 1 or 2.

Default: 0.00%

<6>

Min: 0.00%
Max: 100.00%

<6>

d1-22

(2C4H)

Intermediate Speed 3

Sets intermediate speed reference 3 when d1-18 = 1 or 3.

Default: 0.00%

<6>

Min: 0.00%
Max: 100.00%

<6>

No.(Addr.)

Name

Description

Setting

Page

All Modes

common

_

All Modes

common

_

All Modes

common

_

All Modes

common

_

All Modes

common

_

All Modes

common

_

All Modes

common

_

Advertising