N8-36: high frequency injection level, N8-37: high frequency injection amplitude, N8-84: polarity detection current – Yaskawa L1000E AC Drive Technical Manual for CIMR-LE Models for Elevator Applications User Manual

Page 237: 9 n: special adjustments

Advertising
background image

5.9 n: Special Adjustments

YASKAWA ELECTRIC SIEP YAIL1E 01A YASKAWA AC Drive L1000E Technical Manual

237

P

a

ra

me

te

r De

ta

ils

5

Setting 2: Pulse injection

A pulse signal is injected into the motor in order to detect the rotor position.

n8-36: High Frequency Injection Level

Sets the frequency level used for High Frequency Injection.

n8-37: High Frequency Injection Amplitude

Sets the amplitude for High Frequency Injection as a percentage of the voltage (200 V or 400 V).

n8-81: High Frequency Injection during Rescue Operation

Sets the frequency used for High Frequency Injection during Rescue Operation.

n8-82: High Frequency Injection Amplitude during Rescue Operation

Sets the amplitude for High Frequency Injection during Rescue Operation as a percentage of the voltage (200 V or 400
V).

n8-84: Polarity Detection Current

Sets the current level (E5-03) as a percentage for detecting polarity during Initial Polarity Estimation.

n8-86: Magnet Pole Search Error Detection Selection

Enables fault detection for Initial Polarity Estimation (dv8).

Setting 0: Disabled

After searching for the rotor pole position one time, the drive starts using the detected rotor position. If the detected
position is wrong, an error occurs when the drive attempts to run the motor. The initial pole search takes approximately
1.5 s.

Setting 1: Enabled

The rotor pole position search is executed multiple times. The drive starts using the detected rotor position only if there is
no difference between the search results. Otherwise a dv8 error will be output. The initial pole search takes approximately
1.5 to 5.0 s.

No.

Parameter Name

Setting Range

Default

n8-36

High Frequency Injection

25 to 1000 Hz

500 Hz

No.

Parameter Name

Setting Range

Default

n8-37

High Frequency Injection Amplitude

0.0 to 99.9%

20.0%

No.

Parameter Name

Setting Range

Default

n8-81

High Frequency Injection during Rescue Operation

25 to 1000 Hz

90 Hz

No.

Parameter Name

Setting Range

Default

n8-82

High Frequency Injection Amplitude during Rescue Operation

0.1 to 99.9%

15.0%

No.

Parameter Name

Setting Range

Default

n8-84

Polarity Detection Current

0 to 150%

100%

No.

Parameter Name

Setting Range

Default

n8-86

Magnet Pole Search Error Detection Selection

0 or 1

0