5.1 A: Initialization

152

YASKAWA ELECTRIC SIEP YAIL1E 01A YASKAWA AC Drive L1000E Technical Manual

Notes on Parameter Initialization

The parameters shown in

Table 5.1

will not be reset when the drive is initialized by setting A1-03 = 2220 or 3330.

Although the control mode in A1-02 is not reset when A1-03 is set to 2220 or 3330, it may change when an application
preset is selected.

Table 5.1 Parameters not Changed by Drive Initialization

A1-04, A1-05: Password and Password Setting

Parameter A1-04 enters the password when the drive is locked; parameter A1-05 is a hidden parameter that sets the
password.

How to use the Password

The user can set a password in parameter A1-05 to restrict access to the drive. The password must be entered to A1-04 to
unlock parameter access (i.e., parameter setting A1-04 must match the value programmed into A1-05). The following
parameters cannot be viewed or edited until the value entered to A1-04 correctly matches the value set to A1-05: A1-01,
A1-02, A1-03, A1-06, and A2-01 through A2-33.

The instructions below demonstrate how to set password “1234”. An explanation follows on how to enter that password
to unlock the parameters.

Table 5.2 Setting the Password for Parameter Lock

No.

Parameter Name

A1-00

Language Selection

A1-02

Control Method Selection

E1-03

V/f Pattern Selection

E5-02

Motor Rated Capacity (for PM)

E5-03

Motor Rated Current (for PM)

E5-04

Motor Poles (for PM)

E5-05

Motor Stator Resistance (for PM)

E5-06

Motor d-Axis Inductance (for PM)

E5-07

Motor q-Axis Inductance (for PM)

E5-09

Motor Induction Voltage Constant 1 (for PM)

E5-24

Motor lnduction Voltage Constant 2

F6-††

Communications Parameter (initialized when F6-08 = 1)

L8-35

Installation Selection

o2-04

Drive Model Selection

No.

Parameter Name

Setting Range

Default

A1-04

Password

0000 to 9999

0000

A1-05

Password Setting

Step

Display/Result

1.

Turn on the power to the drive. The initial display appears.

2.

Press

or

until the Parameter Setting Mode screen appears.

3.

Press

to enter the parameter menu tree.

- MODE -

U1-01= 0.00%

U1-02= 0.00%
U1-03= 0.00A

DRV

Speed Ref (OPR)

Rdy

RSEQ
LREF

FWD

HELP

- MODE -

PRG

DATA

Programming

FWD

-PRMSET-

Initialization

Select Language

PRG

FWD

A

1-00=

0