A.2 Three-Phase 400 V Class Drives

YASKAWA ELECTRIC SIEP YAIL1E 01A YASKAWA AC Drive L1000E Technical Manual

359

Spe

c

if

ic

at

ions

A

A.2 Three-Phase 400 V Class Drives

Table A.2 Power Ratings (Three-Phase 400 V Class)

Item

<1> The motor capacity (HP) refers to a NEC rated 4-pole motor. The rated output current of the drive output amps should be equal to or greater than

the motor current. Select the appropriate capacity drive if operating the motor continuously above motor nameplate current.

<2> Assumes operation at the rated output current. Input current rating varies depending on the power supply transformer, input reactor, wiring

conditions, and power supply impedance.

<3> DC is not available for UL standards.

<4> Rated motor capacity is calculated with a rated output voltage of 440 V.

<5> Carrier frequency can be set up to 8 kHz while keeping this current rating. Higher carrier frequency settings require derating.

<6> Carrier frequency can be set up to 5 kHz while keeping this current rating. Higher carrier frequency settings require derating.

Specification

CIMR-LE4A

0009

0012

0019

0023

0030

0039

0049

0056

0075

0094

0114

0140

0188

0225

0260

Maximum Applicable Motor

Capacity (HP)

<1>

5

7.5

10

15

20

25

30

40

50

60

75

100

125

150

175

Input

Input Current (A)

<2>

8.2

10.4

15

20

29

39

44

43

58

71

86

105

142

170

207

Rated Voltage

Rated Frequency

Three-phase 380 to 480 Vac 50/60 Hz 510 to 680 Vdc

<3>

Allowable Voltage

Fluctuation

-15 to 10%

Allowable Frequency

Fluctuation

±5%

Input Power (kVA)

8.1

10.0

14.6

19.2

28.4

37.5

46.6

39.3

53.0

64.9

78.6

96.0

129.9

155

189

Output

Rated Output

Capacity (kVA)

<4>

5.5

<5>

7

<5>

11.3

<5>

13.7

<5>

18.3

<5>

24

<5>

30

<5>

34

<5>

48

<5>

57

<5>

69

<5>

85

<6>

114

<6>

137

<6>

165

<6>

Rated Output

Current

(3 minutes, 50% ED)

(A)

9.0

<5>

11.5

<5>

18.5

<5>

22.5

<5>

30.0

<5>

38.8

<5>

48.8

<5>

56.3

<5>

75.0

<5>

93.8

<5>

113.8

<5>

140.0

<6>

187.5

<6>

225.0

<6>

260.0

<6>

Overload Tolerance

133% of rated output current for 30 s

Carrier Frequency

User adjustable between 2 and 15 kHz

User adjustable between 2 and 10 kHz

Maximum Output

Voltage (V)

Three-phase 380 to 480 V (proportional to input voltage)

Maximum Output

Speed (Hz)

120 Hz (user-adjustable)

Advertising