F1-20: pg option card disconnect detection 1, F1-29: dev detection condition selection, F1-50: encoder selection – Yaskawa L1000E AC Drive Technical Manual for CIMR-LE Models for Elevator Applications User Manual

Page 188: F1-51: pgoh detection level, Commo n, 6 f: option settings, Selects when dev error detection is active, Θ + cos, Θ = 1

Advertising
background image

5.6 F: Option Settings

188

YASKAWA ELECTRIC SIEP YAIL1E 01A YASKAWA AC Drive L1000E Technical Manual

F1-20: PG Option Card Disconnect Detection 1

Sets whether the drive detects a fault when a speed feedback card is disconnected.

Setting 0: Disabled
Setting 1: Enabled

F1-29: dEv Detection Condition Selection

Selects when dEv error detection is active.

Setting 0: After speed reference, SFS output and motor speed have matched once.
Setting 1: After speed reference, SFS output have matched once.
Setting 2: Always during Run.

Figure 5.15

Figure 5.15 Speed Deviation Detection Conditions Flowchart

F1-50: Encoder Selection

Sets up the type of encoder connected to a PG-F3 option card.

Setting 0: EnDat 2.1/01, 2.2/01 Serial Communications operation + Sin/Cos
Setting 1: EnDat 2.2/22 Serial Communications operation
Setting 2: Hiperface

The use of EnDat2.2/22 encoders requires a PG-F3 option with software version 0102 or later.

To identify the PG-F3 software version refer to the PG-F3 labeling in the field designated “C/N” (S + four digit number).”

F1-51: PGoH Detection Level

Sets the level for detecting PG Hardware Fault (PGoH).

Usually the relation between the sin and cos track is

. If the value of the square root falls below the

level set in F1-51, a speed feedback hardware fault is detected. Available when F1-20 = 1.

No.

Parameter Name

Setting Range

Default

F1-20

PG Option Card Disconnect Detect 1

0 or 1

1

No.

Parameter Name

Setting Range

Default

F1-29

dEv Detection Condition Selection

0 to 2

2

No.

Parameter Name

Setting Range

Default

F1-50

Encoder Selection

0 to 2

0

No.

Parameter Name

Setting Range

Default

F1-51

PGoH Detection Level

1 to 100%

80%

Speed reference

Speed

Soft Starter Output and Calculating
the Speed Reference

Motor speed

: Setting 2

: Setting 1

: Setting 0

C

B

A

A

B

C

Time

commo

n_

sin

2

θ + cos

2

θ = 1

Advertising