5.11 S: Elevator Parameters

YASKAWA ELECTRIC SIEP YAIL1E 01A YASKAWA AC Drive L1000E Technical Manual

263

P

a

ra

me

te

r De

ta

ils

5

S6-05: Brake Response Error (SE4) Detection Time

Sets a delay time for detecting a brake response error (SE4). SE4 is detected when an output terminal set for “Brake
release” (H2-†† = 50) and an input terminal set for “Brake feedback” (H1-†† = 79) do not match for the time set to
S6-05.

S6-10: Overacceleration Detection Level

If the elevator car accelerates at an abnormal rate, the drive triggers an overacceleration fault (dv6) and the motor coasts
to stop. Parameter S6-10 determines the acceleration rate that triggers the dv6 fault. A setting of 0.0 m/s

2

disables

overacceleration detection.

S6-11: Overacceleration Detection Time

Sets the time that the acceleration must exceed the overacceleration detection level before as fault is triggered.

S6-12: Overacceleration Detection Selection

Determines the conditions for detecting an overacceleration situation.

Setting 0: Always enabled
Setting 1: During run only

S6-15: Speed Reference Loss Detection

Enabled or disables detection for missing speed reference (FrL).

Setting 0: Disabled
Setting 1: Enabled

S6-16: Restart after Baseblock Selection

Allows the drive to restart the motor after returning to normal operation from Baseblock state (H1-†† = 8/9) or from
Safe Torque-Off state (Safe Disable inputs H1 and H2 enabled) while the Up/Down command is still active.

Setting 0: No restart after Baseblock or Safe Torque-Off

Do not restart the motor when leaving the Baseblock or Safe Torque-Off state even if an Up/Down command is still
active.

No.

Parameter Name

Setting Range

Default

S6-05

Brake Response Error (SE4) Detection Time

0 to 10000 ms

500 ms

No.

<1> Default setting is determined by parameter o1-03. If o1-03 is set to 0 through 5, the default is 1.5 m/s

2

. If o1-03 is set to 6, the default is

5.0 ft/s

2

(setting range: 0.0 to 50.0 ft/s

2

).

Parameter Name

Setting Range

Default

S6-10

Overacceleration Detection Level

0.0 to 20.0 m/s

2

1.5 m/s

2

<1>

No.

Parameter Name

Setting Range

Default

S6-11

Overacceleration Detection Time

0 to 5000 ms

50 ms

No.

Parameter Name

Setting Range

Default

S6-12

Overacceleration Detection Selection

0 or 1

0

No.

Parameter Name

Setting Range

Default

S6-15

Speed Reference Loss Detection

0 or 1

1

No.

Parameter Name

Setting Range

Default

S6-16

Restart after Baseblock Selection

0 or 1

0