5.11 S: Elevator Parameters

262

YASKAWA ELECTRIC SIEP YAIL1E 01A YASKAWA AC Drive L1000E Technical Manual

S5-12: Stop Distance

Sets the stopping distance when Stop Distance Control is enabled. Refer to

Direct Landing on page 260

and

Leveling

Distance Control on page 261

for details.

S5-13: Direct Landing Minimum Speed Level

Sets the speed level for the start of Direct Landing. Direct Landing is disabled if the starting speed for Direct Landing is
less than the maximum output speed multiplied by this parameter (E1-04

× S5-13).

S6: Faults for Elevator Applications

S6-01: Motor Contactor Response Error (SE1) Detection/Reset Selection

Determines when the drive should detect a motor contactor response error (SE1). SE1 is triggered if there is no response
from the motor contactor within the time set in S6-10 after the contactor control output has been set.

Setting 0: Detect during stop, SE1 must be manually reset
Setting 1: Detect during stop, SE1 can be automatically reset
Setting 2: No SE1 detection

S6-02: Starting Current Error (SE2) Detection Delay Time

Sets a delay time for starting current error (SE2). SE2 is detected when the drive output current is below 25% after the
Up/Down command has been entered and the brake release time and the time set to S6-02 have both passed. The brake
control command will not be issued (brake stays applied).

S6-03: SE2 Detect Current Level

Sets the level of current applied to the motor when the Brake Control command is activated, as a percentage of the Motor
No-load Current (E2-03). A Starting Current Error (SE2) occurs when the drive's output current is less than the value in
S6-03 after both the Brake Release Delay Time (S1-06) and the SE2 Detection Delay Time (S6-02) have passed after a
RUN command.

S6-04: Output Current Error (SE3) Detection Delay Time

Sets a delay time for detecting an output current fault (SE3). SE3 is detected when the drive output current drops below
25% after the brake has released.

No.

Parameter Name

Setting Range

Default

S5-12

<1> The setting range becomes 0.00 to 393.00 inches when the length units are set for inches (o1-12 = 1).

Stop Distance

0 to 10000 mm

<1>

0 mm

No.

Parameter Name

Setting Range

Default

S5-13

Direct Landing Minimum Speed Level

0 to 100%

20%

No.

Parameter Name

Setting Range

Default

S6-01

Motor Contactor Response Error (SE1) Detection/Reset Selection

0 to 2

0

No.

Parameter Name

Setting Range

Default

S6-02

Starting Current Error (SE2) Detection Delay Time

0.00 to [S1-04 - S1-06]

200 ms

No.

Parameter Name

Setting Range

Default

S6-03

SE2 Detect Current Level

0 to 100 %

25 %

No.

Parameter Name

Setting Range

Default

S6-04

Output Current Error (SE3) Detection Delay Time

0 to 5000 ms

200 ms