Common_tmonly, 2 mechanical installation – Yaskawa L1000E AC Drive Technical Manual for CIMR-LE Models for Elevator Applications User Manual

Page 44

Advertising
background image

2.2 Mechanical Installation

44

YASKAWA ELECTRIC SIEP YAIL1E 01A YASKAWA AC Drive L1000E Technical Manual

Internal/Flush-Mount

An internal flush-mount requires an installation support set that must be purchased separately. Contact a Yaskawa
representative to order an installation support set and mounting hardware.

Figure 2.9

illustrates how to attach the

Installation Support Set A.

1.

Cut an opening in the enclosure panel for the LED monitor operator as shown in

Figure 2.10

.

2.

Mount the LED monitor to the installation support.

3.

Mount the installation support set and LED monitor to the enclosure panel.

Figure 2.8

Figure 2.9 Internal/Flush Mount Installation

Note: Use a gasket between the enclosure panel and the LED monitor in environments with a significant amount of dust or other

airborne debris.

Figure 2.9

Figure 2.10 Panel Cut-Out Dimensions (Internal/Flush-Mount Installation)

Enclosure panel

Unit: mm

Digital Operator

Installation Support Set A

M4 × 10
Phillips truss head screw × 4
(for panel widths between 1 and 1.6)

M3

× 6

Phillips recessed
pan head machine screw × 2

common_TMonly

120

45

59

+0.5
0

89

+0.5

0

Unit : mm

common_TMonly

Advertising