5.11 S: Elevator Parameters

254

YASKAWA ELECTRIC SIEP YAIL1E 01A YASKAWA AC Drive L1000E Technical Manual

S3-34: Anti-Rollback Torque Bias 1

Sets an intermediary value for the torque bias used for Anti-Rollback when Position Lock at start is performed. This
setting rarely needs to be changed.

S3-35: Anti-Rollback Torque Bias 2

Sets a maximum value for the torque bias used for Anti-Rollback when Position Lock at start is performed. This setting
rarely needs to be changed.

S3-37: Position Deviation Level to Apply Anti-Rollback Torque Bias 1

Sets the position deviation level to activate at Anti-Rollback Torque Bias 1 (S3-34). This setting rarely needs to be
changed.

S3-38: Position Deviation Level to Apply Anti-Rollback Torque Bias 2

Determines the position deviation level when the drive should switch from the Anti-Rollback torque bias set in S3-34 to
the torque bias set in S3-35. This setting rarely needs to be changed.

S3-39: Anti-Rollback Integral Gain

Determines the drive responsiveness for Anti-Rollback during Position Lock.

Increasing the value set to S3-39 may help if there is still too much deviation from the Position Lock start position after
Position Lock gain 1 and gain 2 have already been adjusted. Lower S3-39 if oscillation occurs. This parameter rarely
needs to be changed.

S3-40: Anti-Rollback Movement Detection

Sets the amount of speed feedback signal pulses to detect a movement of the rotor.

S3-41: Position Lock Gain at Start 2 Reduction

Sets a reduction factor for the Position Lock Gain at Start 2 (Anti Rollback Gain) set in parameter S3-02.

If the motor rotation (i.e., car movement) is below the movement detection level set to S3-40, the drive will reduce the
Anti-Rollback gain according to the gain reduction level set in S3-41.

No.

Parameter Name

Setting Range

Default

S3-34

Anti-Rollback Torque Bias 1

0.0 to 100.0%

0.0%

No.

Parameter Name

Setting Range

Default

S3-35

Anti-Rollback Torque Bias 2

0.0 to 100.0%

0.0%

No.

Parameter Name

Setting Range

Default

S3-37

Position Deviation Level to Apply Anti-Rollback Torque Bias 1

0 to 32767

0

No.

Parameter Name

Setting Range

Default

S3-38

Position Deviation Level to Apply Anti-Rollback Torque Bias 2

0 to 32767

0

No.

Parameter Name

Setting Range

Default

S3-39

Anti-Rollback Integral Gain

-30.00 to 30.00

0.00

No.

Parameter Name

Setting Range

Default

S3-40

Anti-Rollback Movement Detection

0 to 100 pulses

1 pulse

No.

Parameter Name

Setting Range

Default

S3-41

Position Lock Gain at Start 2 Reduction

0.00 to 1.00

0.50

Advertising