S5-01: short floor operation selection, S5-02: nominal speed for short floor calculation, S5-03: short floor minimum constant speed time – Yaskawa L1000E AC Drive Technical Manual for CIMR-LE Models for Elevator Applications User Manual

Page 258: 11 s: elevator parameters, Enables and disables the short floor function

Advertising
background image

5.11 S: Elevator Parameters

258

YASKAWA ELECTRIC SIEP YAIL1E 01A YASKAWA AC Drive L1000E Technical Manual

S5-01: Short Floor Operation Selection

Enables and disables the Short Floor function.

Note: 1. The Short Floor and Advanced Short Floor functions cannot be used during Rescue Operation.

2. Do not use Short Floor or Advanced Short Floor when the analog input terminals are configured to supply the speed reference.
3. The drive will accelerate or decelerate to the specified speed reference at the specified Accel/Decel rate if the speed priority is set for

multi-step speed reference (d1-18 = 0 or 3) and the leveling speed reference is selected during Short Floor or Advanced Short Floor.

Setting 0: Disabled
Setting 1: Enabled (Short Floor Operation)
Setting 2: Enabled (Advanced Short Floor Operation)

S5-02: Nominal Speed for Short Floor Calculation

Determines the rated speed used to calculate the distance for the Short Floor function when speed priority is set for Multi-
step Speed Reference (d1-18 = 0 or 3).

S5-03: Short Floor Minimum Constant Speed Time

Sets the minimum time of the constant speed operation when the Advanced Short Floor function is enabled (S5-01 = 2).

Constant speed

operation at

less than the

rated speed

Not Available.

Before start

Operates at the leveling speed.

No.

Parameter Name

Setting Range

Default

S5-01

Short Floor Operation Selection

0 to 2

0

No.

Parameter Name

Setting Range

Default

S5-02

Nominal Speed for Short Floor Calculation

0.0 to 100.0%

0.0%

No.

Parameter Name

Setting Range

Default

S5-03

Short Floor Minimum Constant Speed Time

0 to 2.0 s

0.0 s

Leveling Speed

Input Timing

Short Floor

Advanced Short Floor

(The speed is 40% of the nominal speed or more.)

H1-

= 53

(Leveling Speed)

d1-19
(Nominal Speed)

d1-26
(Leveling Speed)

40% of nominal
speed

ON(close)

0

Operating
speed

Time

(The speed is less than 40% of the nominal speed.)

H1-

= 53

(Leveling Speed)

d1-19
(Nominal Speed)

d1-26
(Leveling Speed)

40% of nominal
speed

ON(close)

0

Operating
speed

Time

Advertising