6.3 Fault Detection

YASKAWA ELECTRIC SIEP YAIL1E 01A YASKAWA AC Drive L1000E Technical Manual

277

T

ro

ubles

hoo

ting

6

Digital Operator Display

Fault Name

CPF03

Control Board Connection Error
Connection error between the control board and the drive

Cause

Possible Solution

There is a connection error.

• Turn off the power and check the connection between the control board and the drive
• If the problem continues, replace the control board or the entire drive. Contact Yaskawa or a Yaskawa representative for

instructions on replacing the control board.

Drive fails to operate properly due to noise interference.

• Check the various options available to minimize the effects of noise.
• Counteract noise in the control circuit, main circuit, and ground wiring.
• Use only recommended cables or other shielded line. Ground the shield on the controller side or on the drive input power side.
• Ensure that other equipment such as switches or relays do not cause noise and use surge absorbers if required.
• Separate all communication wiring from drive power lines. Install an EMC noise filter to the drive power supply input.

Digital Operator Display

Fault Name

CPF06

EEPROM Memory Data Error
An error in the data saved to EEPROM

Cause

Possible Solution

There is an error in EEPROM control circuit.

• Turn off the power and check the connection between the control board and the drive.
• If the problem continues, replace the control board or the entire drive. Contact Yaskawa or a Yaskawa representative for

instructions on replacing the control board.

The power supply was switched off while parameters
were being saved to the drive.

Reinitialize the drive (A1-03).

Power to the control board was lost while writing
parameter settings during Rescue Operation.

Reinitialize the drive (A1-03).

Digital Operator Display

Fault Name

CPF07

Terminal Board Connection Error

CPF08

Cause

Possible Solution

There is a faulty connection between the terminal board
and control board.

• Turn off the power and check the connection between the control board and the drive.
• If the problem continues, replace the control board or the entire drive. Contact Yaskawa or a Yaskawa representative for

instructions on replacing the control board.

Digital Operator Display

Fault Name

to

,

to

<1>

CPF11 to CPF14,

CPF16 to CPF21

Control Circuit Error

Cause

Possible Solution

Hardware is damaged.

• Cycle power to the drive.
• If the problem continues, replace the control board or the entire drive. Contact Yaskawa or a Yaskawa representative for

instructions on replacing the control board.

Digital Operator Display

Fault Name

CPF22

Hybrid IC Failure

Cause

Possible Solution

Hybrid IC failure on the power board

• Cycle power to the drive.

Refer to Diagnosing and Resetting Faults on page 304

.

• If the problem continues, replace the control board or the entire drive. Contact Yaskawa or a Yaskawa representative for

instructions on replacing the control board.

Digital Operator Display

Fault Name

CPF23

Control Board Connection Error
Connection error between the control board and the drive

Cause

Possible Solution

Hardware is damaged.

• Turn the power off and check the connection between the control board and the drive.
• If the problem continues, replace the control board or the entire drive. Contact Yaskawa or a Yaskawa representative for

instructions on replacing the control board.

Digital Operator Display

Fault Name

CPF24

Drive Unit Signal Fault
The drive capacity cannot be detected correctly (drive capacity is checked when the drive is powered up).

Cause

Possible Solution

Hardware is damaged.

If the problem continues, replace the control board or the entire drive. Contact Yaskawa or a Yaskawa representative for
instructions on replacing the control board.

Digital Operator Display

Fault Name

CPF25

Terminal Board not Connected

Cause

Possible Solution

Terminal board is not connected correctly.

Reconnect the terminal board to the connector on the drive, then cycle the power to the drive.