5.7 H: Terminal Functions

H parameters are used to assign functions to the external terminals.

H1: Multi-Function Digital Inputs

NOTICE: Always turn off the RUN command before changing the setting of parameters d1-18 (Speed Reference Selection Mode), b1-

01 (Speed Reference Selection), or H1-

†† (Multi-Function Digital Inputs). If the RUN command is on when changing any of these

settings, the motor may unexpectedly start running, and could result in injury.

H1-03 to H1-08: Functions for Terminals S3 to S8

These parameters assign functions to the multi-function digital inputs. The various functions and their settings are listed
in

Table 5.9

.

Table 5.9 Multi-Function Digital Input Terminal Settings

Setting 3 to 5: Multi-Step Speed Reference 1 to 3

Switches multi-step speed frequency references d1-01 to d1-08 by digital inputs.

Refer to Speed Selection Using Digital

Inputs (b1-01 = 0) on page 121

for details.

Setting 6: Jog reference selection

When the speed reference is not assigned to the input terminals (b1-01

≠ 1), then the Jog frequency will be activated every

time an input terminal set for the Jog frequency reference closes. Note that the speed reference priority selection in d1-18
may disable the Jog frequency.

Table 5.10 Speed Reference Priority and Jog Frequency

No.

<1> With the speed reference priority d1-18 is set to 0 or 3, the default settings for parameters H1-03 to H1-07 governing input terminals S3 to S7

are: 24, 14, 3, 4, and 5 respectively. When d1-18 is set to 1 or 2, the default settings for H1-03 to H1-07 become 50, 54, 51, 53, and F

respectively.

Parameter Name

Setting

Range

Default

H1-03

Terminal S3 Function Selection

3 to 79

Determined by d1-18

<1>

H1-04

Terminal S4 Function Selection

3 to 79

H1-05

Terminal S5 Function Selection

3 to 79

H1-06

Terminal S6 Function Selection

3 to 79

H1-07

Terminal S7 Function Selection

3 to 79

H1-08

Terminal S8 Function Selection

3 to 79

F: Through Mode

Setting

Function

Page

Setting

Function

Page

3

Multi-Step Speed Reference 1

193

20 to 2F

External Fault

196

4

Multi-Step Speed Reference 2

50

Nominal Speed

196

5

Multi-Step Speed Reference 3

51

Intermediate Speed

196

6

Jog reference selection

193

52

Releveling Speed

196

7

Accel/decel Ramp Selection 1

194

53

Leveling Speed

197

8

Baseblock Command (N.O.)

194

54

Inspection Operation

197

9

Baseblock Command (N.C.)

55

Rescue Operation

197

F

Not used (Through Mode)

194

56

Motor Contactor Feedback

197

14

Fault Reset

194

57

High Speed Limit Up

197

15

Fast Stop (N.O.)

194

58

High Speed Limit Down

197

16

Motor 2 selection

195

5A

Motor Contactor Feedback 2

197

17

Fast Stop (N.C.)

194

5B

Brake Feedback 2

197

18

Timer Function Input

195

5C

Stop Distance Correction

197

1A

Accel/decel Ramp Selection 2

195

67

Communications Test Mode

197

79

Brake Feedback

197

d1-18 (Speed Reference

Selection Mode)

Jog Frequency

0

Multi-speed references take priority, and the leveling speed in d1-26 is used for the Jog frequency.

1

Jog frequency cannot be used.

2

Jog frequency cannot be used.