B.3 Parameter Table

YASKAWA ELECTRIC SIEP YAIL1E 01A YASKAWA AC Drive L1000E Technical Manual

389

Pa

ra

met

er

L

is

t

B

◆ L: Protection Functions

L parameters provide protection to the drive and motor, including control during momentary power loss, Stall Prevention,
frequency detection, fault reset, overtorque detection, torque limits, and other types of hardware protection.

■

L1: Motor Protection

■

L2: Undervoltage Detection

■

L3: Stall Prevention

No. (Addr.)

Name

Description

Setting

Page

L1-01

(480H)

<1> Default setting is determined by the control mode (A1-02).

Motor Overload Protection
Selection

0: Disabled
1: General purpose motor (standard fan cooled)
2: Drive dedicated motor with a speed range of 1:10
3: Vector motor with a speed range of 1:100
5: PM motor with constant torque characteristics

Default:

<1>

Min: 0
Max: 5

213

L1-02

(481H)

Motor Overload Protection Time

Sets the motor thermal overload protection (oL1) time.

Default: 1.0 min

Min: 0.1 min
Max: 5.0 min

215

L1-03

(481H)

Motor Overheat Alarm Operation
Selection (PTC thermistor input)

Sets operation when the motor temperature analog input (H3-02 or H3-10 = E) exceeds the oH3
alarm level.
0: Ramp to stop
1: Coast to stop
2: Emergency Stop (Fast Stop) (decelerate to stop using the deceleration time in C1-09)
3: Alarm only (“oH3” will flash)

Default: 3

Min: 0
Max: 3

216

L1-04

(481H)

Motor Overheat Fault Operation
Selection (PTC thermistor input)

Sets stopping method when the motor temperature analog input (H3-02 or H3-10 = E) exceeds
the oH4 fault level.
0: Ramp to stop
1: Coast to stop
2: Emergency Stop (Fast Stop) (decelerate to stop using the deceleration time in C1-09)

Default: 1

Min: 0
Max: 2

217

L1-05

(481H)

Motor Temperature Input Filter
Time (PTC thermistor input)

Adjusts the filter for the motor temperature analog input (H3-02 or H3-10 = E).

Default: 0.20 s

Min: 0.00 s
Max: 10.00 s

217

L1-13

(46DH)

Continuous Electrothermal
Operation Selection

0: Disabled
1: Enabled

Default: 1

Min: 0
Max: 1

215

No. (Addr.)

Name

Description

Setting

Page

L2-05

(489H)

<9> Values shown here are for 200 V class drives. Double the value when using a 400 V class drive.

<15> Default setting value is dependent on the setting for the input voltage (E1-01).

Undervoltage Detection Level
(Uv)

Sets the DC bus undervoltage trip level.

Default:

<9> <15>

Min: 150 Vdc
Max: 210 Vdc

<9>

217

No. (Addr.)

Name

Description

Setting

Page

L3-01

(48FH)

Stall Prevention Selection during
Acceleration

0: Disabled.
1: General purpose. Acceleration is paused as long as the current is above the L3-02 setting.
2: Intelligent. Accelerate in the shortest possible time without exceeding the L3-02 level.

Default: 1

Min: 0
Max: 2

217

L3-02

(490H)

Stall Prevention Level during
Acceleration

Used when L3-01 = 1 or 2. 100% is equal to the drive rated current.

Default:

<16>

Min: 0%
Max: 150%

<16>

219

L3-05

(493H)

Stall Prevention Selection during
Run

0: Disabled. Drive runs at a set frequency. A heavy load may cause speed loss.
1: Decel time 1. Uses the deceleration ramp set to C1-02 while Stall Prevention is performed.
2: Decel time 2. Uses the deceleration ramp set to C1-04 while Stall Prevention is performed.

Default: 1

Min: 0
Max: 2

219

L3-06

(494H)

Stall Prevention Level during Run

Enabled when L3-05 is set to 1 or 2. 100% is equal to the drive rated current.

Default:

<16>

Min: 30%
Max: 150%

<16>

219

All Modes

common

_

All Modes

common

_

All Modes

common

_

All Modes

common

_

All Modes

common

_

All Modes

common

_

All Modes

common

_

common

_

CLV

CLV/PM

V/f

OLV

common

_

CLV

CLV/PM

V/f

OLV

common

_

CLV

CLV/PM

V/f

OLV

common

_

CLV

CLV/PM

V/f

OLV