B.3 Parameter Table

YASKAWA ELECTRIC SIEP YAIL1E 01A YASKAWA AC Drive L1000E Technical Manual

389

Pa

ra

met

er

L

is

t

B

L: Protection Functions

L parameters provide protection to the drive and motor, including control during momentary power loss, Stall Prevention,
frequency detection, fault reset, overtorque detection, torque limits, and other types of hardware protection.

L1: Motor Protection

L2: Undervoltage Detection

L3: Stall Prevention

No. (Addr.)

Name

Description

Setting

Page

L1-01

(480H)

<1> Default setting is determined by the control mode (A1-02).

Motor Overload Protection
Selection

0: Disabled
1: General purpose motor (standard fan cooled)
2: Drive dedicated motor with a speed range of 1:10
3: Vector motor with a speed range of 1:100
5: PM motor with constant torque characteristics

Default:

<1>

Min: 0
Max: 5

213

L1-02

(481H)

Motor Overload Protection Time

Sets the motor thermal overload protection (oL1) time.

Default: 1.0 min

Min: 0.1 min
Max: 5.0 min

215

L1-03

(481H)

Motor Overheat Alarm Operation
Selection (PTC thermistor input)

Sets operation when the motor temperature analog input (H3-02 or H3-10 = E) exceeds the oH3
alarm level.
0: Ramp to stop
1: Coast to stop
2: Emergency Stop (Fast Stop) (decelerate to stop using the deceleration time in C1-09)
3: Alarm only (“oH3” will flash)

Default: 3

Min: 0
Max: 3

216

L1-04

(481H)

Motor Overheat Fault Operation
Selection (PTC thermistor input)

Sets stopping method when the motor temperature analog input (H3-02 or H3-10 = E) exceeds
the oH4 fault level.
0: Ramp to stop
1: Coast to stop
2: Emergency Stop (Fast Stop) (decelerate to stop using the deceleration time in C1-09)

Default: 1

Min: 0
Max: 2

217

L1-05

(481H)

Motor Temperature Input Filter
Time (PTC thermistor input)

Adjusts the filter for the motor temperature analog input (H3-02 or H3-10 = E).

Default: 0.20 s

Min: 0.00 s
Max: 10.00 s

217

L1-13

(46DH)

Continuous Electrothermal
Operation Selection

0: Disabled
1: Enabled

Default: 1

Min: 0
Max: 1

215

No. (Addr.)

Name

Description

Setting

Page

L2-05

(489H)

<9> Values shown here are for 200 V class drives. Double the value when using a 400 V class drive.

<15> Default setting value is dependent on the setting for the input voltage (E1-01).

Undervoltage Detection Level
(Uv)

Sets the DC bus undervoltage trip level.

Default:

<9> <15>

Min: 150 Vdc
Max: 210 Vdc

<9>

217

No. (Addr.)

Name

Description

Setting

Page

L3-01

(48FH)

Stall Prevention Selection during
Acceleration

0: Disabled.
1: General purpose. Acceleration is paused as long as the current is above the L3-02 setting.
2: Intelligent. Accelerate in the shortest possible time without exceeding the L3-02 level.

Default: 1

Min: 0
Max: 2

217

L3-02

(490H)

Stall Prevention Level during
Acceleration

Used when L3-01 = 1 or 2. 100% is equal to the drive rated current.

Default:

<16>

Min: 0%
Max: 150%

<16>

219

L3-05

(493H)

Stall Prevention Selection during
Run

0: Disabled. Drive runs at a set frequency. A heavy load may cause speed loss.
1: Decel time 1. Uses the deceleration ramp set to C1-02 while Stall Prevention is performed.
2: Decel time 2. Uses the deceleration ramp set to C1-04 while Stall Prevention is performed.

Default: 1

Min: 0
Max: 2

219

L3-06

(494H)

Stall Prevention Level during Run

Enabled when L3-05 is set to 1 or 2. 100% is equal to the drive rated current.

Default:

<16>

Min: 30%
Max: 150%

<16>

219

All Modes

common

_

All Modes

common

_

All Modes

common

_

All Modes

common

_

All Modes

common

_

All Modes

common

_

All Modes

common

_

common

_

CLV

CLV/PM

V/f

OLV

common

_

CLV

CLV/PM

V/f

OLV

common

_

CLV

CLV/PM

V/f

OLV

common

_

CLV

CLV/PM

V/f

OLV