SAN real-time performance data

28

NOTE

Devices with 10 GbE ports must be running Fabric OS 6.4.1 or later to obtain the correct
TE_Port statistics (TX/RX).

NOTE

Devices with 10 GbE ports must have the RMON MIB enabled on the switch. For more
information about the rmon collection command, refer to the Fabric OS Converged Enhanced
Ethernet Command Reference
.

If you selected a host adapter, the Show list of Realtime Port Selector - Hosts dialog box
displays Host ports and Host port measures of the discovered hosts.

3. Right-click anywhere in the Available list and select Expand All from the menu.

4. Select the ports or trunks you want to include in the performance graph in the Available list.

5. Click the right arrow to move the selected ports or trunks to the Selected list.

NOTE

For E_Port trunks, the port node can be moved to the Selected list along with the occupied and
attached ports.

6. Click OK.

The Real Time Performance Graphs dialog box displays.

Filtering real-time performance data

To filter real-time performance data from the Real Time Performance Graphs dialog box, complete
the following steps.

1. Open the Real Time Performance Graphs dialog box.

For step-by-step instructions, refer to

“Generating a real-time performance graph”

on

page 1074.

2. Select how the data is measured, in received frames, transmitted frames, or CRC errors.

For a list of possible performance measures, refer to

“SAN performance measures”

on

page 1068.

3. To select more than one measure, click the Additional Measures expand arrows and select the

check box for each additional measure. If the Additional Measures area is not shown, click the
down arrow.

For a list of possible performance measures, refer to

“SAN performance measures”

on

page 1068.

4. (Optional) Enter a value (percentage) in the Reference Line field to set a reference for the

transmit and receive utilization.

Note that this field is only available when you select Tx % Utilization or Rx % Utilization from the
Measures list.

5. Select how detailed the data will display from the Granularity list. Options are in increments of

10 seconds, 15 seconds, 20 seconds, 25 seconds, 30 seconds, 45 seconds, or 1 minute.