Brocade Network Advisor SAN User Manual

1129

53-1003154-01

Flow Vision flows

29

Flow definitions

To define a flow and configure Flow Vision to monitor that flow, you must provide a unique flow
name and specify the flow parameters. These parameters identify the sets of related frames and
can either be explicitly defined or Flow Vision can learn them through observation.

Flow definitions are stored on the switch on which you create the flow, and are not distributed
across the fabric. This means that each switch knows only its own flows and does not know what
flows exist on other switches.

You can create three types of flows: Monitor, Generator, and Mirror. For specific procedures for
defining flows, refer to the following topics:

“Creating a Flow Monitor flow definition”

on page 1140"

“Creating a Flow Generator flow definition”

on page 1181"

“Creating a Flow Mirror flow definition”

on page 1191"

Flow definition parameters and rules

The rules listed in

Table 88

identify the parameters that can be used to define a flow.

Flow frame type parameters

Frame monitoring can be performed for a variety of frames using predefined frame type
parameters. To access the Frame Type Picker dialog box, click the ellipsis button next to the Frame
Type field on the Add Flow Definition dialog box.

Table 89

lists the frame type parameters and the frames counted for each.

TABLE 88

Flow definition rules

Parameters

Field names

Rules

Port

Ingress
Egress

Only one field must be specified

Values must be explicit

Frame

Source
Destination
LUN
Frame Type

1

1.

Refer to

Table 89

for more information on frame types.

At least one field must be specified

Values for source and destination can be explicit or “*” (“*” indicates a
learned flow)

Values for LUN and frame type must be explicit

TABLE 89

Supported frame type parameters

Frame type parameter Frames counted

abts

Abort sequence frames

baacc

All frames accepted

barjt

All frames rejected

scsi

All SCSI frames (including both command and data frames)

scsiread

Only SCSI read command frames

scsiwrite

Only SCSI write command frames

scsirw

Both SCSI read and write command frames