Database tables and fields

H

TABLE 174

HBA_REMOTE_PORT

Field

Definition

Format

Size

ID Autogenerate

primary

column.

int

SYMBOLIC_NAME

The symbolic name associated with the remote port.

varchar

256

PORT_WWN

The world wide name of the remote device''s port.

char

23

NODE_WWN

The world wide name of the remote device

char

23

NAME

The name associated with the device

varchar

256

FC_ADDRESS

FC Address for the port in hex

varchar

6

FRAME_DATA_SIZE

The frame size, in bytes, of the device.
The default value is 512.

int

SPEED

Operating speed of the remote port.

int

STATE

Indicates whether the device is online or offline.
The default value is ‘Offline’.

varchar

64

SUPPORTED_COS

The types of classes that are supported on the
remote port; for example, Class-3

varchar

32

DEVICE_TYPE

The type of the device; for example, Disk or Tape.

varchar

64

BIND_TYPE

The persistent bind type. The default value is 0.

smallint

TARGET_ID

The identifier of the target device. The default value
is 0.

int

ROLE

The role of the device (target or initiator)

varchar

64

VENDOR

The vendor of the device

varchar

256

PRODUCT_ID

The device''s identifier.

varchar

256

PRODUCT_VERSION

Field which stores information regarging target rate
limiting on the remote port

varchar

256

QOS_PRIORITY

QOS Priority on the target. The default value is
'Unknown'.

varchar

64

QOS_FLOW_ID

QOS Flow ID on the target. The default value is 0.

varchar

64

CURRENT_SPEED

Current speed of the remote port, as enforced by
TRL.
The default value is 0.

varchar

64

TRL_ENFORCED

True if TRL(Target Rate limit) is enforced.

varchar

16

BUS_NO

Channel number in the PCI Bus. The default value is
0.

varchar

32

FCP_IM_STATE

Indicates whether the Fibre Channel Protocol Input
Method (FCP-IM) is online or offline.

varchar

128

IO_LATENCY_MIN

Minimum IO Latency value (< 79) in milliseconds and
is calculated when HBA port starts SCSI (FCP)
exchanges

varchar

32

IO_LATENCY_MAX

IO Latency value in milliseconds and is calculated
when HBA port starts SCSI (FCP) exchanges

varchar

32

IO_LATENCY_AVERAGE

Average IO Latency value in milliseconds and is
calculated when HBA port starts SCSI (FCP)
exchanges

varchar

32

Advertising