Flow Monitor

29

FIGURE 497

Add Flow Definition dialog box

3. Enter a name for the flow in the Name field.

The name cannot be over 20 characters and can only include alphanumeric characters or
underscores.

NOTE

For a physical switch, the name must be unique. However, for logical switches, the name does
not have to be unique.

4. Select the Monitor check box.

5. Select one of the following options to define the flow direction:

Source to Destination — Select to define the flow direction from an ingress port to an
egress port, or a source device (in traffic) to a destination device (out traffic).

Bidirectional — Select to define the flow direction to be monitored in both directions.

NOTE

You cannot use the LUN and Bidirectional parameters in a flow definition.

6. If you want to persist this flow definition over reboots, select the Persist over switch reboots

check box.

7. If you want to immediately activate the flow after creation, select the Activate all selected

features check box.

8. Change target switch for the flow definition by clicking the ellipsis button to the right of the

Target Switch field.