Brocade Network Advisor SAN User Manual v12.3.0 User Manual

Page 1303

Advertising
background image

Brocade Network Advisor SAN User Manual

1251

53-1003154-01

Viewing a configuration policy manager report

31

Switch Checks — Switch checks provide the following information for each selected check:

Name — Product name.

Status — Result of the check and reason for failure if known. Valid results include
Passed, Partially Failed, Failed, Not Applicable, and Unknown.

Switch Checks include the following options:

Switch — Check for at least Configured_Minimum_Value connections to neighboring
switches. This check provides the following additional detail for this check:

-

Neighboring Switch — Name of the neighboring switch.

-

Connection Count — Number of connections to the neighboring switch.

Switch — Check for HTTPS (secure HTTP) configuration. This check provides the
following additional detail for this check:

-

HTTPs Status — Whether HTTPS is enabled or disabled on the product.

-

HTTP Status — Whether HTTP is enabled or disabled on the product.

Switch — Check if the product is configured to send events to this server.

Switch — Check if the product is configured to send Upload Failure Data Capture
information to an FTP server.

Switch - Check for SSH (secure Telnet) configuration. This check provides the following
additional detail for this check:

-

SSH Status — Whether SSH is enabled or disabled on the product.

-

Telnet Status — Whether Telnet is enabled or disabled on the product.

Switch - Check for SNMPv3 (secure SNMP) configuration. This check provides the
following additional detail for this check:

-

SNMPv3 Status — Whether SNMPv3 is enabled or disabled on the product.

-

SNMP Status — Whether SNMP is enabled or disabled on the product.

Switch - Check for MAPS actions enabled (SAN only). This check provides the following
details:

-

RAS Log Event — Whether the RAS log event action is enabled or disabled on the
switch.

-

Port Decommission — Whether the Port Decommission event action is enabled or
disabled on the switch

-

SNMP Trap — Whether the SNMP Trap event action is enabled or disabled on the
switch.

-

Fence — Whether the Fence event action is enabled or disabled on the switch.

-

E-mail — Whether the e-mail event action is enabled or disabled on the switch.

-

SFP Status Marginal — Whether the SFP Status Marginal event action is enabled
or disabled on the switch.

-

Switch Status Marginal — Whether the Switch Status Marginal event action is
enabled or disabled on the switch.

-

Switch Status Critical — Whether the Switch Status Critical event action is enabled
or disabled on the switch.

Configuration Rule Checks — Switch checks provide the following information for each
selected check:

-

Block/Condition Name — Name of the block or condition.