Flow monitor limitations – Brocade Network Advisor SAN User Manual v12.3.0 User Manual

Page 1191

Advertising
background image

Brocade Network Advisor SAN User Manual

1139

53-1003154-01

Flow Monitor

29

Flow Monitor limitations

The following limitations apply to all Flow Monitor flows:

Only one active learned flow is supported per ASIC.

Only supports learned flows on 16 Gbps-capable FC platforms.

For scsiread, scsiwrite, and scsirdwr frame type parameters, only monitors SCSI 6-, 10-, 12-,
and 16-bit Read and Write values. Flow Monitor cannot monitor Read Long and Write Long
values.

Flow Monitor is not supported on ports with Encryption or Compression enabled.

Flow Monitor can monitor IFL flows only on EX_Ports in an FC router.

Flow Monitor cannot monitor Inter-Fabric Link (IFL) flows on E_Ports or F_Ports.

Flow Monitor cannot monitor flows that are using frame redirection for encryption.

You cannot convert Flow Monitor flows to Fabric OS 7.1.x flow performance monitors.

The calculated Rx and Tx frame size values displayed in the output are accurate within a range
of -4 through +8 bytes. For example, a frame size value of 256 bytes may actually be anywhere
from 252 to 264 bytes.

The following restrictions apply to parameter usage in Flow Monitor flow definitions:

You cannot use the LUN and Bidirectional parameters in a flow definition.

You cannot use the Frame Type, LUN, and Bidirectional parameters for learned flows.

Flow creation is not allowed if Advanced Performance Monitor (APM) or Port Mirroring is
enabled. Similarly, APM and Port Mirroring-related operations are not allowed if any flow (active
or defined) is present on the switch.

The following limitations apply to 16 Gbps-capable FC platforms, including the FC8-32E and
FC8-48E blades:

They support a maximum of 2 flows defined using a combination of ingress port and frame
type parameters per ASIC chip.

Each port supports a maximum of 12 flows defined using both egress port and frame type
parameters.

Flow Monitor can only monitor flows that are using EX_Ports.

The following limitations apply to 8 Gbps-capable FC platforms and blades:

You cannot create a flow definition using both ingress port and frame type parameters.

Each port supports a maximum of 12 flows defined using both egress port and frame type
parameters, except for the following Fabric OS devices, which only support a maximum of 8
flows per port.

-

24-port, 8 Gbps FC Switch

-

32-port, 8 Gbps FC Switch

-

64-port, 8 Gbps FC Switch

-

Embedded 12-port, 8 Gbps Switch

-

Embedded 24-port, 8 Gbps Switch

-

Embedded 16-port, 8 Gbps Switch

-

Embedded 24-port, 8 Gbps Switch

-

8 Gbps Extension Switch