Fru monitoring category, Security monitoring category – Brocade Network Advisor SAN User Manual v12.3.0 User Manual

Page 1393

Advertising
background image

Brocade Network Advisor SAN User Manual

1341

53-1003154-01

MAPS monitoring categories

33

FRU monitoring category

The FRU category enables you to define rules for field replaceable units (FRU), including ports,
power supplies, and flash memory.

Table 114

lists measures in the FRU category and describes each measure. Possible states for all

FRU measures are faulty, inserted, on, off, ready, and up.

Security monitoring category

The Security category monitors different security violations on the switch and takes action based
on the configured thresholds and their actions.

Table 115

lists measures in the Security category and describes what each measure indicates.

BB_FCR_CNT

Tracks the number of Fibre Channel routers present on the backbone fabric.

ZONE_CFGSZ_PER

Tracks the zone configuration size limit per switch.

TABLE 114

FRU measures

Measure

Description

Power Supplies (PS_STATE)

State of a power supply has changed.

Fans (FAN_STATE)

State of a fan has changed.

Blades (BLADE_STATE)

State of a blade has changed.

SFPs (SFP_STATE)

State of the SFP has changed.

WWN

State of a world wide name (WWN) card has changed.

TABLE 115

Security measures

Measure

Description

DCC violations (SEC_DCC)

An unauthorized device attempts to log in to a secure fabric.

HTTP violations (SEC_HTTP)

A browser access request reaches a secure switch from an unauthorized IP
address.

Illegal command (SEC_CMD)

Commands permitted only to the primary fabric configuration server (FCS)
are executed on another switch.

Incompatible security DB (SEC_IDB) Secure switches with different version stamps have been detected.

Login violations (SEC_LV)

Login violations that occur when a secure fabric detects a login failure.

Invalid certifications (SEC_CERT)

There is a missing or invalid certificate file.

No-FCS (SEC_FCS)

The switch has lost contact with the primary FCS.

SCC violations (SEC_SCC)

SCC violations that occur when an unauthorized switch tries to join a secure
fabric. The WWN of the unauthorized switch appears in the ERRLOG.

Security authentication failures
(SEC_AUTH_FAIL)

Authentication failures that occur when packets try to pass from a
nonsecure switch to a secure fabric.

TABLE 113

Fabric measures (Continued)

Measure

Description

Advertising