San end-to-end monitoring, San end-to-end monitoring 0 – Brocade Network Advisor SAN User Manual v12.3.0 User Manual

Page 1142

Advertising
background image

1090

Brocade Network Advisor SAN User Manual

53-1003154-01

SAN end-to-end monitoring

28

SAN end-to-end monitoring

Procedures in this section pertain to end-to-end monitoring using the legacy End-to-End Monitor
feature instead of using Flow Vision to create end-to-end monitors.

For systems using Fabric OS version 7.2 or later, when you select a device or device port, and then
select Monitor > Performance > End-to-End Monitors, a message displays that you can use Flow
Vision to provide End-to-End monitoring. You have these options:

To use Flow Vision, delete existing monitors, then use the Add Flow Definition dialog box to
define an initiator and target port pair for monitoring. Refer to

Chapter 29, “Flow Vision”

for

more information.

Clicking OK, opens the legacy Set End-To-End Monitors dialog box.To use the legacy End-to-End
Monitor feature, you must deactivate existing flows defined for the switch for Flow Vision.

Refer to the following important notes when using this feature:

For systems using Fabric OS version 7.2 or later, you can create end-to-end monitors using the
Flow Vision feature. Refer to

Chapter 29, “Flow Vision”

for details.

End-to-end monitoring requires a Fabric OS device.

An end-to-end monitor and a Top Talker monitor cannot be configured on the same fabric or
external F_Port application-specific integrated circuit (ASIC). You must delete the Top Talker
monitor before you configure the end-to-end monitor.

Current

FC

SNMP

.1.3.6.1.4.1.1588.2.1.1.1.28.1.1.3

Rx Power

FC

SNMP

.1.3.6.1.4.1.1588.2.1.1.1.28.1.1.4

Tx Power

FC

SNMP

.1.3.6.1.4.1.1588.2.1.1.1.28.1.1.5

Invalid Oredered Set

FC

SNMP

.1.3.6.1.3.94.4.5.1.45

BB Credit Zero

FC

SNMP

1.3.6.1.3.94.4.5.1.8

Truncated Frames

FC

SNMP

1.3.6.1.3.94.4.5.1.47

FEC Corrected Blocks

FC

SNMP

1.3.6.1.4.1.1588.2.1.1.1.27.1.31

FEC Uncorrected Blocks

FC

SNMP

1.3.6.1.4.1.1588.2.1.1.1.27.1.32

Latency

FCIP

SNMP

.1.3.6.1.4.1.1588.4.1.1.5

Dropped Packets

FCIP

SNMP

.1.3.6.1.4.1.1588.4.1.1.3

Link Retransmits

FCIP

SNMP

.1.3.6.1.4.1.1588.4.1.1.2

Timeout Retransmits

FCIP

SNMP

.1.3.6.1.4.1.1588.4.1.1.9

Fast Retransmits

FCIP

SNMP

.1.3.6.1.4.1.1588.4.1.1.10

Duplicate Ack Received

FCIP

SNMP

.1.3.6.1.4.1.1588.4.1.1.11

Window Size RTT

FCIP

SNMP

.1.3.6.1.4.1.1588.4.1.1.12

TCP Out of Order Segments FCIP

SNMP

.1.3.6.1.4.1.1588.4.1.1.13

SlowStart Status

FCIP

SNMP

.1.3.6.1.4.1.1588.4.1.1.14

CRC Errors

EE Monitors HTTP

PortCRC (variable from the return html file)

TABLE 85

Performance counters

Counter name

Type

Protocol

Source OID value