Report content and functions – Brocade Network Advisor SAN User Manual v12.3.0 User Manual

Page 313

Advertising
background image

Brocade Network Advisor SAN User Manual

261

53-1003154-01

Reports

6

Report content and functions

Each report contains the following information:

The name of the report displayed at the top of the report.

The date and time the report was generated.

The report data, presented in a tabular format.

Depending on the report type, you can perform the following functions:

Sort a table by clicking a column head. Click a column head again to reverse the sort order.

Launch a more detailed report by clicking a link within the report.

Navigate through the report using a table of contents (TOC), by clicking the TOC icon in the
Report toolbar.

Export report data to a CSV, PDF, or XLS file by clicking the Export Data icon in the toolbar (refer
to

“Downloading a generated report”

on page 237 or

“Exporting data from the report”

on

page 262).

Navigate through the report by using the following icons in the Report toolbar.

Length Cu

The length of the copper cable (for distances greater than 1 meter, where optimum
performance is required).

Vendor Name

The vendor of the extended link.

Vendor OUI

The vendor’s organizational unique identifier (OUI).

Vendor Part

The part number of the extended link.

Revision

The revision level of the extended link.

Wavelength

The wavelength translation, which enables longer reach through lower attenuation.

Options

Displays details about the transceiver; for example, the type of port connector, type of
transceiver, and enable/disable status.

BR Max

The upper bit rate limit at which the SFP transceiver meets its specifications.

BR Min

The lower bit rate limit at which the SFP transceiver meets it specifications.

Serial #

The serial number of the SFP transceiver.

Date Code

The date the SFP was manufactured transceiver.

Temperature (c)

The port temperature, measured in Celsius.

Bias Current (mA)

The low-level DC current (the Bias Current), measured in mA.

Tx Power (mW)

The transmitted power, measured in mW.

Rx Power (mW)

The received power, measured in mW.

Voltage (V)

The voltage; for example, 1.8V, 3.3V, or 5.0V.

Alarm/Warning

Indicates whether an alarm has been triggered.

TABLE 25

Adapters Faulty SFP report fields and components (Continued)

Field/Component

Description

Advertising