Brocade Network Advisor SAN User Manual v12.3.0 User Manual

Page 1462

Advertising
background image

1410

Brocade Network Advisor SAN User Manual

53-1003154-01

Host adapter reports

35

Encoding

Displays how the extended link is encoded, for example, 8B10B.

Baud Rate

The transmission rate, roughly equivalent to the number of bits per second.

Length 9U1

The length of the single-mode fiber-optic cable, used in situations where gigabit
performance is not required (for distances greater than 100 meters).

Length 9U2

The length of the single-mode fiber-optic cable, used in situations where gigabit
performance is not required (for distances greater than 100 meters).

Length 50u

The length of the 50u fiber-optic cable (for distances greater than 10 meters).

Length 62.5u

The length of the 62.5u fiber-optic cable (for distances greater than 10 meters).

Length Cu

The length of the copper cable (for distances greater than 1 meter, where optimum
performance is required).

Vendor Name

The vendor of the extended link.

Vendor OUI

The vendor’s organizational unique identifier (OUI).

Vendor Part

The part number of the extended link.

Revision

The revision level of the extended link.

Wavelength

The wavelength translation, which enables longer reach through lower attenuation.

Options

Displays details about the transceiver; for example, the type of port connector, type of
transceiver, and enable/disable status.

BR Max

The upper bit rate limit at which the SFP transceiver meets its specifications.

BR Min

The lower bit rate limit at which the SFP transceiver meets it specifications.

Serial #

The serial number of the SFP transceiver.

Date Code

The date the SFP was manufactured transceiver.

Temperature (c)

The port temperature, measured in Celsius.

Bias Current (mA)

The low-level DC current (the Bias Current), measured in mA.

Tx Power (mW)

The transmitted power, measured in mW.

Rx Power (mW)

The received power, measured in mW.

Voltage (V)

The voltage; for example, 1.8V, 3.3V, or 5.0V.

Alarm/Warning

Indicates whether an alarm has been triggered.

TABLE 126

Adapters Faulty SFP report fields and components (Continued)

Field/Component

Description

Advertising