Brocade Network Advisor SAN User Manual v12.3.0 User Manual

Page 1295

Advertising
background image

Brocade Network Advisor SAN User Manual

1243

53-1003154-01

Adding a configuration policy manager

31

The selected fabrics display in the Selected Fabrics list.

7. To set configuration policy managers for switches, select the Switch/Router Checks tab

(

Figure 531

) and complete the following steps.

FIGURE 531

Add Configuration Policy Manager dialog box, Switch/Router Checks tab

a. Select one or more of the following checks in the Available Checks list to include them in

the configuration policy manager:

For more information about these checks and fixes for rule violations, refer to

“Switch and

router configuration policy managers”

on page 1233.

Select the Check if the product is configured to send events to this server to
determine if the Management application server is registered as an SNMP recipient
and syslog recipient.

Select the Check for redundant connections to neighboring switches (SAN only) check
box to determine if there are at least the minimum number of configured ISLs
between each switch pair.

Select the Check for HTTPS (secure HTTP) configuration check box to check each
target to see if HTTPS is active for device data transmission.

Select the Check if the product is configured to send Upload Failure Data Capture to
an FTP server (SAN only) check box to determine the following configurations:
– Upload Failure Data Capture is enabled on the selected switches.
– A configured FTP Server is accessible.
– You have write permission to the directory.

Select the Check for SSH (secure Telnet) configuration check box to check each target
to see if SSH is enabled for device data transmission.