Examples of circuit failover in groups – Brocade Network Advisor SAN User Manual v12.3.0 User Manual

Page 992

Advertising
background image

940

Brocade Network Advisor SAN User Manual

53-1003154-01

FCIP trunking

22

A valid failover group requires at least one metric 0 circuit and at least one metric 1 circuit. If
you do not configure these, a warning will display. If there is no metric 0 circuit and only a
metric 1 circuit, the metric 1 circuit will be used, regardless of whether there are metric 0
circuits in another failover group.

The number of valid failover groups defined per tunnel is limited by the number of circuits that
you can create for the switch model. For an 8 Gbps Extension Blade, you can configure up to 5
valid groups on an 10-circuit tunnel. On an 8 Gbps Extension Switch, you could have up to 3
valid groups because you can only configure 6 circuits per tunnel.

Consider available WAN bandwidth requirements when configuring failover circuit groups.
Refer to

“Bandwidth calculation during failover”

on page 938.

Examples of circuit failover in groups

Tables

Table 72

through

Table 74

provide examples of how failover occurs on circuits with different

bandwidths configured in failover groups.

Table 72

illustrates circuit failover in a tunnel with two failover groups, each with two circuits. All

data through the tunnel is initially load balanced over Circuits 1 and 2. The following occurs during
circuit failover:

If circuit 1 fails, circuit 3 becomes active and data is load balanced over circuit 2 and 3.

If circuit 2 fails, circuit 4 becomes active and data is load balanced over circuit 1 and 4.

If both circuit 1 and 2 fail, circuit 3 and.4 become active and data is load balanced over both
circuits.

Table 73

illustrates circuit failover in a tunnel with one failover group containing three circuits, In

this case, failover occurs as if circuits are not part of a failover group. Circuit 2 and 3, both with
metric 1, become active only after circuit 1 with metric 0 fails.

TABLE 72

Tunnel with two failover groups with two circuits

Circuits in tunnel

Failover group ID

Circuit bandwidth

In use for tunnel data

Circuit 1
Metric 0

1

500Mb

If active, yes.

Circuit 2
Metric 0

2

1000Mb

If active, yes.

Circuit 3
Metric 1

1

500Mb

Only when circuit 1
fails.

Circuit 4
Metric 1

2

1000Mb

Only when circuit 2
fails.

TABLE 73

Tunnel with one failover groups with three circuits

Circuits in tunnel

Failover group ID

Circuit bandwidth

In use for tunnel data

Circuit 1
Metric 0

1

1000Mb

If active, yes.

Circuit 2
Metric 1

1

500Mb

Only when circuit 1
fails.

Circuit 3
Metric 1

1

500Mb

Only when circuit 1
fails.

Advertising