Supported flow parameters, Number of supported flows – Brocade Network Advisor SAN User Manual v12.3.0 User Manual

Page 1183

Advertising
background image

Brocade Network Advisor SAN User Manual

1131

53-1003154-01

Flow Vision flows

29

Support for 16 Gbps F_Ports and F_Port trunks is provided on the following devices:

-

Switches: 24-port, 48-port, and 96-port 16 Gbps switches

-

Chassis: 4-slot and 8-slot 16 Gbps Backbone Chassis

-

Blades: FC8-32E, FC8-48E, FC16-32, FC16-48, and FC16-64

Disabling a SIM-port that is receiving traffic may produce Class 3 discards for the simulated
traffic; however, this will have no effect on other traffic flows.

Supported flow parameters

Table 91

lists the supported flow configuration parameters for the Flow Vision Generator, Monitor,

and Mirror features.

Number of supported flows

On chassis-based platforms, Flow Vision supports a maximum of 512 user-defined flows. On
fixed-port platforms, Flow Vision supports a maximum of 128 user-defined flows. However, there is
a combined limit from all features of 64 flows (including static flows, root flows, and sub-flows,
whether active or inactive) for any one port. In addition, there are individual limits for each Flow
Vision feature;

Table 92

lists these limits. When you create a flow, Flow Vision verifies that there is

no identical active flow.

Refer to the individual features for feature-specific restrictions.

TABLE 91

Supported flow parameters

Parameter

Flow Generator

Flow Monitor

Flow Mirror

Ingress switch port

Supported

Supported

Supported

Egress switch port

Supported

Supported

Supported

Source end device

Supported

Supported

Supported

Destination end device

Supported

Supported

Supported

Source FID/VFID

Supported

Supported

Supported

Destination FID/VFID

Supported

Supported

Supported

Bidirectional

Not applicable

Supported

Supported

Mirror port

Not applicable

Not applicable

Supported

LUN ID

Not applicable

Supported

Supported

Frame type

Not applicable

Supported

Supported

TABLE 92

Feature-specific flow count restrictions in Flow Vision

Feature

Limit to number of flows

Flow Monitor

Up to 64 active flows per port, including static flows, root flows, and sub-flows.

Flow Generator

Up to 4 active flows per port, including static flows, root flows, and sub-flows.

Flow Mirror

One active flow per switch.

Advertising