San feature-to-firmware requirements – Brocade Network Advisor SAN User Manual v12.3.0 User Manual

Page 81

Advertising
background image

Brocade Network Advisor SAN User Manual

29

53-1003154-01

SAN feature-to-firmware requirements

1

SAN feature-to-firmware requirements

Use the following table to determine whether the Management application SAN features are only
available with a specific version of the Fabric OS firmware as well as if there are specific licensing
requirements.

XML RPC 1.2-B1

Open Source

YourKitJavaProfiler 9.5.1

YourKit License

TABLE 7

Open source software third-party software products

Open Source Software

License Type

TABLE 8

SAN feature to firmware requirements

Feature

Fabric OS

Access Gateway (AG)

AG connected to Fabric OS devices requires firmware 5.2 or later.

Call Home (Trial and Licensed version Only) Requires Fabric OS 5.2 or later for supportSave.

Requires Fabric Watch license for SNMP traps.

Configuration Management

Requires Fabric OS 5.3 or later

Discovery

Requires Fabric OS 5.0 or later for the seed switch in a pure Fabric OS fabric.
Requires Fabric OS 6.0 or later for the seed switch in a mixed Fabric OS and M-EOS fabric.

Encryption (Trial and Licensed version Only)

Requires Fabric OS 6.1.1_enc or 6.2 or later.

Enhanced Group Management (Trial and
Licensed version Only)

Requires Enhanced Group Management license.

Fault Management

Requires Fabric OS 4.4 or later for SNMP traps

Fabric Binding (Trial and Licensed version
Only)

Requires Fabric OS 5.2 or later in a pure Fabric OS fabric.
Requires Fabric OS 6.0 or later in a mixed Fabric OS and M-EOS fabric.

FCIP Management

Requires Fabric OS 5.1 or later to modify.
Requires Fabric OS 5.3 or later for FCIP tunnels.
Requires FCIP license.
Requires Fabric OS 6.0 or later to enable the FICON Emulation tab on the FCIP Tunnel
Advanced Settings dialog box.

FCoE Management

Requires FCoE license on the device.
Requires Fabric OS version v6.1.2_CEE or later.

FICON (Trial and Licensed version Only)

Requires Fabric OS 5.2 or later for cascaded FICON.
Requires Fabric OS 6.0 or later for advanced FICON.
Requires Fabric OS 6.1.1 or later to configure multiple Allow/Prohibit matrices.
Requires FICON CUP license to allow CUP management features.

Firmware Management

Requires Fabric OS 5.0 or later.
Requires Fabric OS 6.1.1 or later on 8G devices.
Requires Enhanced Group Management license to perform group actions.

High Integrity Fabric

Requires Fabric OS 5.2 or later in a pure Fabric OS fabric.
Requires Fabric OS 6.0 or later in a mixed Fabric OS and M-EOS fabric.