Configuring a frame monitor flow

You can use the Frame Type field to create a frame monitor flow. For more information about frame
monitoring, refer to

“Frame Monitor”

on page 1959". The following example creates a Flow Monitor

flow that counts SCSI Read-Write (scsirw) frames egressing port 2 of the switch on which the flow is
running.

1. Right-click a switch port (2) on which you want to monitor frames and select Fabric Vision >

Flow > Add.

The Add Flow Definition dialog box displays with the following criteria and flow identifiers
pre-populated:

Feature — Monitor

Direction — Bidirectional

Source Device — Source identifier

Destination Device — * (an asterisk allows you to use any port)

Egress port — port number (2)

2. Enter a name (scsirw) for the flow definition in the Name field.

The name cannot be over 20 characters and can only include alphanumeric characters or
underscores.

NOTE

For a physical switch, the name must be unique. However, for logical switches, the name does
not have to be unique.

3. Select the Persist over switch reboots check box to persist this flow definition over reboots.

4. Select the Activate all selected features check box to immediately activate the flow after

creation.

5. Enter an asterisk (*) in the Destination field.

6. Enter the frame type (scsirw) in the Frame Type field.

To select a frame type from a list, click the ellipsis button. Refer to

“Flow frame type

parameters”

on page 1129" for a list of the supported frame type parameters.

7. Click OK.

The Flow Vision dialog box displays with the new flow definition highlighted.

8. Select OK to save the definition.

When the flow definition activates, the Flow Vision dialog box displays with the new flow
selected (highlighted) in the Flow Definitions table. To review the sub-flow data for the selected
flow, refer to

“Monitoring a Flow Monitor flow”

on page 1149".