Brocade Network Advisor SAN User Manual v12.3.0 User Manual

Page 1589

Advertising
background image

Brocade Network Advisor SAN User Manual

1537

53-1003154-01

Database tables and fields

H

UNREACHABLE_TIME

Time when the switch becomes unreachable.

timestamp

OPERATIONAL_STATUS

Chassis operational status like FRU, Power Supply
etc..

varchar

128

CREATION_TIME

Core switch record creation time. This tells us when
the intial discovery has happened.

timestamp

LAST_SCAN_TIME

Last scan time tells the time when the last time the
switch was polled.

timestamp

LAST_UPDATE_TIME

Last update time tells the time when the last update
to the database record happened.

timestamp

SYSLOG_REGISTERED

Determies whether the switch is registered for
sending syslog traps.

1 is registered

0 is not registered.

smallint

CALL_HOME_ENABLED

Determines whether the call home feature is
enabled..

smallint

SNMP_REGISTERED

Determines whether the switch is registered for
sending SNMP traps .

1 is registered

0 is not registered.

smallint

USER_IP_ADDRESS

Applicable for McDATA switches and VCS clusters.
McDATA Switches - This column is used to store the
IP address which user provides for those M-model
switches for which seed switch is unable to return IP
address.

VCS clusters - This column is used to store the IP
address given by the user during discovery time. For
profile based discovery, we will populate the seed
switch IP address selected by the system.

varchar

128

NIC_PROFILE_ID

Nic Profile ID refers to the entry in the NIcProfile table
that has IP Address of the Management application
which is used as Syslog or SNMP reciepients.

int

MANAGING_SERVER_IP_
ADDRESS

IP address(v4/v6) of the Management application
server which is currently managing the M-model
switch. Used for M-EOS switch only. It does not apply
to Fabric OS switches.

varchar

128

VF_ENABLED

Determines whether Virtual Fabric is enabled on the
switch.

1 is enabled

0 is disabled

smallint

VF_SUPPORTED

Determines whether virtual fabric is supported on
the switch.

1 is supported

0 is unsupported

smallint

MANAGED_ELEMENT_ID

A unique managed element ID for this physical
switch. Also a foreign key reference to the
MANAGED_ELEMENT table.

int

TABLE 70

CORE_SWITCH (Continued)

Field

Definition

Format

Size

Advertising