Call Home Event Tables

B

TABLE 128

# Thermal Events

Event reason code

FRU code/Event type

Description

Severity

800

DVP/LIM/HW

High temperature warning.

3

801

DVP/LIM/HW

Critically hot temperature warning.

3

802

DVP/LIM/HW

Port card shutdown due to thermal violations.

3

805

SWM/SBAR/HW

High temperature warning.

3

806

SWM/SBAR/HW

Critically hot temperature warning.

3

807

SWM/SBAR/HW

SBAR module shutdown due to thermal violations.

3

810

CTP/HW

High temperature warning.

3

811

CTP/HW

Critically hot temperature warning.

3

812

CTP/HW

CTP shutdown due to thermal violations.

3

850

CTP/HW

System shutdown due to CTP thermal threshold violations.

4

TABLE 129

Fabric OS Events

Event reason code

FRU code/Event type

Description

Severity

N/A

Ethernet

Switch is not reachable.

3

N/A

SW-Missing

Switch is missing from the fabric.

3

1009

MS-1009

Error in registered link incident record (RLIR).

4

1021

MAPS-1021

Core blade redundancy

3

1021

MAPS-1021

Error ports

3

1021

MAPS-1021

Faulty CPs

3

1021

MAPS-1021

Faulty or absent Blades

3

1021

MAPS-1021

Faulty or absent Fans

3

1021

MAPS-1021

Faulty or absent Power Supplies

3

1021

MAPS-1021

Faulty Ports

3

1021

MAPS-1021

Faulty Temperature sensors

3

1021

MAPS-1021

Faulty WWN Cards

3

1021

MAPS-1021

Flash usage is out of range

3

1021

MAPS-1021

Marginal ports

3

1021

MAPS-1021

Missing SFPs

3

1402

FW-1402

Flash usage is out of range (Fabric OS version 6.0 or earlier).