User-defined performance monitors

7

9. (Top N, Bottom N, and Distribution monitors only) Configure threshold numbers and associated

colors by completing the following steps.

Depending on the monitor type you select, you can define up to four threshold numbers in
increasing or decreasing order and up to five associated threshold colors.

(Top N and Bottom N monitors only) The decreasing order defaults are as follows: 90 and
above displays red, 75 and above displays orange, 60 and above displays yellow, and all others
display blue. The maximum values allowed are -32,768 through 32,767 for SFP power and
0 through 32,767 for all other measures.

(Distribution monitors only) The increasing order defaults are as follows: 0 through 20 displays
green, 21 through 40 displays blue, 41 through 60 displays yellow, 61 through 80 displays
orange, and 81 through 100 displays red.

a. (Top N and Bottom N monitors only) Select the check box.

b. Enter a number in the field.

c. Click the color square to launch the Color dialog box.

To pick a color from a swatch, select the Swatches tab. Select a color from the display.

To specify a color based on hue, saturation, and brightness, click the HSV tab. Specify
the hue (0 through 360 degrees), saturation (0 through 100%), value (0 through
100%), and transparency (0 through 100%).

To specify a color based on hue, saturation, and lightness, click the HSL tab. Specify
the hue (0 through 360 degrees), saturation (0 through 100%), lightness (0 through
100%), and transparency (0 through 100%).

To specify a color based on values of red, green, and blue, click the RGB tab. Specify
the values for red (0 through 255), green (0 through 255), blue (0 through 255), and
alpha (0 through 255).

To specify a color based on values of cyan, magenta, yellow, and black, click the CMYK
tab. Specify the values for cyan (0 through 255), magenta (0 through 255), yellow (0
through 255), black (0 through 255), and alpha (0 through 255).

To reset to the default color, click Reset.

10. (Time series monitors only) Add targets for the monitor by clicking Add and completing steps in

“Adding targets to a user-defined performance monitor”

on page 335.

Remove targets from the monitor by selecting one or more targets in the Targets list and
clicking Remove.

11. Click OK on the Add Performance Dashboard Monitor dialog box.

The Customize Dashboard dialog box displays with the new monitor in the Performance
Monitors list.

12. Click OK on the Customize Dashboard dialog box.

The new performance monitors display at the bottom of the dashboard.