Creating a flow generator flow definition, Disabling sim-port, Mode – Brocade Network Advisor SAN User Manual v12.3.0 User Manual

Page 1233: Disabling sim-port mode

Advertising
background image

Brocade Network Advisor SAN User Manual

1181

53-1003154-01

Flow Generator

29

Disabling SIM-Port mode

To disable SIM-Port mode, use the following steps.

1. Select the SIM-Port for the source device in the Product List, and then select Monitor > Fabric

Vision > Flow > SIM Mode > Disable.

2. Select the SIM-Port for the destination device in the Product List, and then select Monitor >

Fabric Vision > Flow > SIM Mode > Disable.

Creating a Flow Generator flow definition

This procedure provides step-by-step instructions for configuring a Generator flow definition. For
more specific example procedures, refer to

“Flow Generator example procedures”

on page 1187".

1. Create two SIM-Ports (

“Enabling SIM-Port mode”

on page 1180").

2. Right-click a SIM-Port and select Fabric Vision > Flow > Add.

The Add Flow Definition dialog box displays with the following criteria and flow identifiers
pre-populated:

Feature — Monitor

Direction — Bidirectional

Source Device — Source identifier

Destination Device — * (an asterisk allows you to use any port)

Ingress port — SIM-Port number

3. Enter a name for the flow definition in the Name field.

The name cannot be over 20 characters and can only include alphanumeric characters or
underscores.

NOTE

For a physical switch, the name must be unique. However, for logical switches, the name does
not have to be unique.

4. Clear the Monitor check box.

5. Select the Generator check box.

6. Select the Source to Destination option to gather flow data from the source device to the

destination device.

7. Select the Persist over switch reboots check box to persist this flow definition over reboots.

8. Select the Activate all selected features check box to immediately activate the flow after

creation.

9. Change the target switch for the flow definition by clicking the ellipsis button to the right of the

Target Switch field.

The Select Switch dialog box displays. To manually set the Target Switch, refer to

“Selecting the

target switch from a list of Fabric Vision-capable switches”

on page 1144".

Advertising