523

53-1003154-01

Ports

12

Combined Status — Displays the current status of the port.

NOTE

Requires a 16 Gbps capable port running Fabric OS 7.0 or later.

NOTE

For devices running Fabric OS 7.1 or earlier, the device must have a Fabric Watch license
and threshold monitoring configured for the port. For more information, refer to the Fabric
Watch Administrator’s Guide
.

NOTE

For devices running Fabric OS 7.2 or later, the device must have a Fabric Vision license,
MAPS must be enabled, and threshold monitoring configured for the port. For more
information, refer to the

“Monitoring and Alerting Policy Suite”

on page 1327.

If the port is online and port monitoring is active, displays the current status of the port
based on these five parameters: Transceiver Temp (C), Rx Power, Tx Power, Transceiver
Current (mAmps), and Voltage (mVolts).

If the port is offline, displays the current status of the port based on these two parameters:
Transceiver Temp (C) and Voltage (mVolts).

Status icons:

Warning icon — One of the five parameters exceeds the threshold of that parameter.
The corresponding parameter field displays with a yellow background.

No icon — No parameters exceed the threshold of that parameter.

Unknown icon — The port is not a 16 Gbps capable port or the device is running
Fabric OS 6.4.X or earlier.

Error icon — Unable to retrieve status of the supported port.

Slot/Port # — The slot and port number of the selected fabric. The port number includes
the type of port (FC, TE, GE, or XGE).

FC Address — The Fibre Channel address of the port.

TX Power — The power transmitted to the SFP in dBm and uWatts.

NOTE

The uWatts display requires devices with Fabric OS 6.1.0 and later. Devices running
Fabric OS 6.0.0 and earlier only display dBm.

RX Power — The power received from the port in dBm and uWatts.

NOTE

The uWatts display requires devices with Fabric OS 6.1.0 and later. Devices running
Fabric OS 6.0.0 and earlier only display dBm.

Transceiver Temp (C) — The temperature of the SFP transceiver.

Voltage (mVolts) — The voltage across the port in mVolts.

Transceiver Current (mAmps) — The laser bias current value in mAmps.