Host adapter reports

35

Adapters Faulty SFP report

The Adapters Faulty SFP report lists all Brocade adapters with unsupported or faulty small
form-factor pluggable (SFP) transceivers. This report is only available for Brocade adapters.

For adapters with unsupported SFPs, this report is the same as the Adapters Inventory report
filtered to show only those hosts with adapter ports that have unsupported SFPs. For a complete
list of fields and components of the Adapters Inventory report, refer to the

“Adapters Inventory

report”

on page 1408.

For adapters with degrading SFPs, there are additional columns in the table that show the
SFP/SFP+ and pluggable optical module (POM) properties for the degrading SFP.

Table 126

describes the SFP and POM fields of the Adapters Faulty SFP Report.

Node WWN/MAC

The port’s WWN or MAC address.

Port WWN/MAC

The node’s (parent device) WWN or MAC address.

Type

The type of port, for example, IP-Port, N, or NL.

QoS Enabled

Whether QoS is enabled (True) or disabled (False).

Frame Field Size (Bytes)

The frame field size in bytes.

Media

The type of media; for example, 8G-sw (8 Gbps software).

FC Address

The port’s Fibre Channel address.

Fabric Name

The name of the Fabric.

Zone Alias

The alternate name of the zone.

Fabric Assigned Address

The state (enabled, disabled, or N/A) of the fabric assigned address for the adapter.

WWN Source

The source of the world wide name. Options include:
Fabric — The WWN is assigned from the fabric. The fabric assigned address must be
enabled.
Factory — The WWN is assigned at the factory.
N/A — Not applicable.

Boot Over SAN

Whether Boot over SAN is enabled or disabled.

Max Supported Speed

The maximum speed that is supported on the port. For the FC port, the maximum
speed is 8 Gbps.

Status

The status of the Ethernet port; for example, Linkup or Linkdown.

TABLE 126

Adapters Faulty SFP report fields and components

Field/Component

Description

SFP Supported

Whether the SFP is supported or not.

Connector Type

The type of port connector; for example, LC. SC, or Cu (copper cable).

Transceiver

The type of transceiver; for example, SFP or SFP+.

Media

The type of media for the transceiver; for example, single mode.

Speed

The port speed.

Extended ID

The identifier for the extended link.

TABLE 125

Adapters Inventory report fields and components (Continued)

Field/Component

Description