Database tables and fields

H

SPEED_TYPE

Stores the speed type of the port. It contains one of
the following values:

1 - Indicates speed is in Mbps.

2 - Indicates speed is in Gbps.

int

EXT_TYPE

Refers to the extended type of the port . Eg
Mirror-Port.

varchar

128

TABLE 396

SWITCH_PORT_PERFORMANCE

Field

Definition

Format

Size

PORT_ID

Primary key of the Switch Port.

int

SWITCH_ID

Primary key of Virtual Switch which this port is
present

int

TX

The number of octets or bytes that have been
transmitted by this port. One second periodic polling
of the port. This value is saved and compared with
the next polled value to compute net throughput.
Note, for Fibre Channel, ordered sets are not
included in the count

double
precision

RX

The number of octets or bytes that have been
received by this port. One second periodic polling of
the port. This value is saved and compared with the
next polled value to compute net throughput. Note,
for Fibre Channel, ordered sets are not included in
the count

double
precision

TX_UTILIZATION

The computed value of TX based on speed of port

double
precision

RX_UTILIZATION

'The computed value of RX based on speed of port

double
precision

LINK_FAILURE

Count of link failures. This count is part of the Link
Error Status Block (LESB). (FC-PH 29.8). Note, this is
a Fibre Channel only stat

double
precision

TX_LINK_RESETS

Count of Link resets. This is the number of LRs
received. Note, this is a Fibre Channel only stat

double
precision

RX_LINK_RESETS

Count of Link resets. This is the number LRs
transmitted. Note, this is a Fibre Channel only stat

double
precision

SYNC_LOSSES

Count of instances of synchronization loss detected
at port. This count is part of the Link Error Status
Block (LESB). (FC-PH 29.8). Note, this is a Fibre
Channel only stat.

double
precision

SIGNAL_LOSSES

Count of instances of signal loss detected at port.
This count is part of the Link Error Status Block
(LESB). (FC-PH 29.8). Note, this is a Fibre Channel
only stat

double
precision

SEQUENCE_ERRORS

Count of primitive sequence protocol errors detected
at this port. This count is part of the Link Error Status
Block (LESB). (FC-PH 29.8). Note, this is a Fibre
Channel only stat

double
precision

TABLE 395

SWITCH_PORT (Continued)

Field

Definition

Format

Size

Advertising