Performance statistics counters – Brocade Network Advisor SAN User Manual v12.3.0 User Manual

Page 1140

Advertising
background image

1088

Brocade Network Advisor SAN User Manual

53-1003154-01

SAN historical performance data

28

Performance statistics counters

Table 84

details the formulas used to calculate performance statistics based on counter type and

protocol.

To calculate FC, GE, FCIP and TE port statistics, the Management application uses SNMP to query
the respective object identifiers (OID) (listed in

Table 84

).

To calculate HBA and CNA statistics, the Management application uses APIs provided by HCM.

To calculate end-to-end monitor (EE monitor) statistics, the Management application uses HTTP to
obtain the TX, RX, and CRC error values.

The polling interval for historical graphs is 5 minutes. The polling interval for real-time graphs is
based on the granularity value (configured in the Real Time Graph dialog box).

TABLE 84

Performance statistic counters

Counter name

Type

Protocol Source OID value

Formula

TX

FC

SNMP

.1.3.6.1.3.94.4.5.1.6

TX = (delta value

1

/ (1000 * 1000)) /

(polling interval

2

)

RX

FC

SNMP

.1.3.6.1.3.94.4.5.1.7

RX = (delta value

1

/ (1000 * 1000)) /

(polling interval

2

)

TX

GE

SNMP

.1.3.6.1.2.1.31.1.1.1.10

TX = (delta value

1

/ (1000 * 1000)) /

(polling interval

2

)

RX

GE

SNMP

.1.3.6.1.2.1.31.1.1.1.6

RX = (delta value

1

/ (1000 * 1000)) /

(polling interval

2

)

TX

FCIP

SNMP

.1.3.6.1.2.1.31.1.1.1.10

TX = (delta value

1

/ (1000 * 1000)) /

(polling interval

2

)

RX

FCIP

SNMP

.1.3.6.1.2.1.31.1.1.1.6

RX = (delta value

1

/ (1000 * 1000)) /

(polling interval

2

)

Uncompressed
Tx/Rx MB/sec

FCIP

SNMP

.1.3.6.1.4.1.1588.4.1.1.6

(delta value

1

/ (1000 * 1000)) /

(polling interval

2

)

TX

EE Monitors HTTP

PortRX (variable from the
return html file)

TX = (delta value

1

/ (1000 * 1000)) /

(polling interval

2

)

RX

EE Monitors HTTP

PortTX (variable from the
return html file)

RX = (delta value

1

/ (1000 * 1000)) /

(polling interval

2

)

TX

HBA, CNA

HCM API N/A

TX = (delta value

1

/ (1000 * 1000)) /

(polling interval

2

)

RX

HBA, CNA

HCM API N/A

RX = (delta value

1

/ (1000 * 1000)) /

(polling interval

2

)

TX

TE

SNMP

.1.3.6.1.2.1.31.1.1.1.6

TX = (delta value

1

/ (1000 * 1000)) /

(polling interval

2

)

RX

TE

SNMP

.1.3.6.1.2.1.31.1.1.1.10

RX = (delta value

1

/ (1000 * 1000)) /

(polling interval

2

)

TX% / RX%

FC, GE,
HBA, CNA

N/A

N/A

TX% or RX% = ((TX or RX) /
((105000000 * port speed)*
(polling interval

2

))) * 100

If utilization is less than 1, the value is 0.0.

Advertising