A2: user-specified setting mode – Yaskawa Matrix Converter User Manual
Page 108

5
-8
A2: User-specified Setting Mode
A1-05
Password 2
Used to set a four digit number as the
password.
This parameter is not usually displayed.
When the Password (A1-04) is displayed,
hold down the RESET key and press the
MENU key and the password will be dis-
played.
0 to
9999
0
No
A
A
A
105H
4-13
6-134
Select Password
Parameter
Number
Name
Description
Setting
Range
Default
Change
during
Run
Control
Methods
MEMO-
BUS
Register
Page
Display
V/f
Open
Loop
Vector
Flux
Vector
A2-01 to
A2-32
User parameters
Used to set the parameter numbers that
can be set/read. Maximum 32.
Effective when the Access Level Selec-
tion (A1-01) is set to User Program (1).
Parameters set in A2-01 to A2-32 can be
set/read in programming mode.
b1-01 to
o3-02
-
No
A
A
A
106H to
125H
6-134
User Param 1 to
32
Parameter
Number
Name
Description
Setting
Range
Default
Change
during
Run
Control
Methods
MEMO-
BUS
Register
Page
Display
V/f
Open
Loop
Vector
Flux
Vector