Setting the torque limit in parameters, Set the torque limit value using an analog input – Yaskawa Matrix Converter User Manual

Page 206

Advertising
background image

Machine Protection

6-

41

Multi-Function Analog Input (H3-05, H3-09)

Note: The forward torque limit is the limit value when the analog input signal generates forward torque. This torque limit setting is enabled even when the

analog input signal generates forward torque while the motor is operating (regeneration).

„

Setting the Torque Limit in Parameters

Set individually four torque limits using L7-01 to L7-04 in the following directions: forward drive, reverse
drive, forward regeneration, and reverse regeneration.

„

Set the Torque Limit Value Using an Analog Input

Change the analog input level torque limit value by setting the torque limit in multi-function analog input ter-
minals A2 and A3.

The analog input terminal signal levels are set up as shown when shipped from the factory:

Multi-function analog input terminal A2: 4 to 20 mA
Multi-function analog input terminal A3: 0 to 10

The following diagram shows the relationship between the torque limits.

Fig 6.35 Torque Limit by Analog Input

Set

Value

Function

Contents (100%)

Control Methods

V/f

Open

Loop

Vector

Flux

Vector

10

Positive torque limit

Motor's rated torque

No

Yes

Yes

11

Negative torque limit

Motor's rated torque

No

Yes

Yes

12

Regenerative torque limit

Motor's rated torque

No

Yes

Yes

15

Positive/negative torque limit

Motor's rated torque

No

Yes

Yes

Negative

Reverse operation

Regenerative torque limit

Regenerative torque limit

Forward torque limit

Positive/negative torque limits

Positive/negative torque limits

No. of motor rotations
Forward operation

Negative torque limit

Positive

Output torque