Reducing Noise and Leakage Current

The switching frequency of the output transistors in the MxC can be changed to reduce carrier noise and leak-
age current from the motor.

„

Related Parameters

* 1. Fixed to 2:4 kHz for V/f.

For Open Loop Vector Control, can select from 2:4 kHz or 4:8 kHz (Fixed to 2: 4 kHz for a 200 V class MxC for 45 kW and a 400 V class MxCs for 22

kW and 45 kW).

* 2. Fixed to 2: 4 kHz for 400 V class MxCs for 110 kW and 160 kW.

„

Control Method and Carrier Frequency Settings

Carrier frequency settings are restricted as listed in the following table according to the control method selec-
tion.

* Fixed to 2: 4 kHz for 200 V class MxC for 45 kW and 400 V class MxCs for 22 kW and 45 kW
Note: 1. Fixed to 2: 4 kHz for 400 V class MxCs for 110 kW and 160 kW.

2. The upper limit of the carrier frequency depends on the MxC capacity.

„

Carrier Frequency Setting Precautions

When selecting the carrier frequency, observe the following precautions.

•

Adjust the carrier frequency according to the cases shown below.
If the wiring distance between MxC and motor is long: Set the carrier frequency low. (Use the following
values as guidelines.)

If speed and torque are inconsistent at low speeds: Lower the carrier frequency.
If there is too much leakage current from the MxC: Lower the carrier frequency.
If the metallic noise from the motor is too loud: Raise the carrier frequency.

Parameter

Number

Name

Description

Setting

Range

Default

Change

during

Run

Control Methods

Display

V/f

Open

Loop

Vector

Flux

Vector

C6-02

Carrier Frequency
Selection

Select carrier frequency pattern.
2: 4 kHz
4: 8 kHz
6: 12 kHz

2, 4, or

6

*1 *2

2

No

Q

Q

Q

CarrierFreq Sel

Control Method

Carrier Frequency

V/f Control

2: 4.0 kHz

Open Loop Vector Control

2: 4.0 kHz
4: 8.0 kHz

*

Flux Vector Control

2: 4.0 kHz
4: 8.0 kHz
6: 12.0 kHz

Wiring Length

50 m or less

100 m or less

Over 100 m

C6-02 (Carrier Frequency
Selection) setting

2, 4, or 6

(4, 8, or 12 kHz)

2 or 4

(4 or 8 kHz)

2 (4 kHz)