Digital Operator Functions

6-

125

Digital Operator Functions

This section explains the digital operator functions.

‹

Setting Digital Operator Functions

The user can set digital operator-related parameters such as selecting the digital operator display, multi-func-
tion selections, and copy functions.

„

Related Parameters

* The digital operator shows rpm instead of min

-1

.

Parameter

Number

Name

Description

Setting

Range

Default

Change

during

Run

Control Methods

Display

V/f

Open

Loop

Vector

Flux

Vector

o1-02

User Monitor
Selection After
Power-Up

Sets the monitor item to be displayed when
the power is turned on.
1: Frequency reference
2: Output frequency
3: Output current
4: The monitor item set for o1-01

1 to 4

1

Yes

A

A

A

Power-On Monitor

o1-03

Digital Operator
Display Selection

Sets the units that will be set and displayed for
the frequency reference and frequency moni-
tor.
0: 0.01 Hz units
1: 0.01% units (Maximum output frequency

is 100%)

2 to 39:

min

−1 ∗

units (Sets the motor poles.)

40 to 39999:

User desired display
Set the desired values for setting and dis-
play for the max. output frequency.

Example: When the max. output frequency
value is 200.0, set 12000.

0 to

39999

0

No

A

A

A

Display Scaling

o1-04

Setting unit for fre-
quency parameters
related to V/f char-
acteristics

Set the setting unit for frequency reference-
related parameters.
0: Hz
1: min

−1 ∗

0 or 1

0

No

No

No

A

Display Units

o2-01

Local/Remote Key
Function Selection

Determines if the digital operator LOCAL/
REMOTE key is functional.
0: Disabled.
1: Enabled.

0 or 1

1

No

A

A

A

Local/Remote Key

o2-02

STOP Key Func-
tion Selection

Determines if the STOP key on the digital
operator will stop the MxC when MxC is
operating from external terminals or serial
communication.
0: Disabled.
1: Enabled.

0 or 1

1

No

A

A

A

Oper STOP Key

Set 4-digit number
excluding the decimal
point.
Set the number of digits
below the decimal point
to display.