Removing and attaching the terminal cover, Removing the terminal cover – Yaskawa Matrix Converter User Manual

Page 31

Advertising
background image

1

-12

Removing and Attaching the Terminal Cover

Remove the terminal cover to wire cables to the control circuit and main circuit terminals.

‹

Removing the Terminal Cover

Loosen the screws on the left and right top of the terminal cover. Pull out the terminal cover in the direction of
arrow 1 and then lift up on the terminal in the direction of arrow 2.

Note: For 45 kW and 75 kW MxCs, an additional screw is located in position A as indicated below.

Fig 1.11 Removing the Terminal Cover (Model: CIMR-ACA4011)

„

For 400-V Class MxCs with a Motor Capacity of 110 kW or 160 kW

1. Loosen the mounting screws of the terminal cover and slide the terminal cover downward.

Note: Eight mounting screws are used to install 400 V-class MxCs with a motor capacity of 110 kW or 160 kW.

Do not remove the mounting screws.

If the four mounting screws A are removed, the terminal cover might fall out when the other four mounting screws B are loosened, possibly resulting in

injury.

The terminal cover of a large-capacity MxC is big and heavy. Be careful when removing or reattaching the cover.

Fig 1.12 Removing the Terminal Cover (Example of CIMR-ACA4160)



#



Mounting screws B