-138

„

Detecting Motor Overspeed

An error is detected when the number of motor rotations exceeds the regulated limit. An overspeed (OS) is
detected when a frequency that exceeds the set value in F1-08 continues for longer than the time set in F1-09.
After detecting an overspeed (OS), the MxC stops according to the setting in F1-03.

„

Detecting Speed Difference between the Motor and Speed Reference

An error is detected when the speed deviation (i.e., the difference between the designated speed and the actual
motor speed) is too great. Speed deviation (DEV) situation occurs after speed agree. The difference between
the speed reference and actual workpiece speed is becomes greater than F1-10 and continues for longer than
the time set in F1-11. After a speed deviation situation is detected, the MxC stops according to the setting in
F1-04.

‹

Using Digital Output Cards

There are two types of MxC digital output cards:

DO-02C
Relay contact output (DPDT contact)

DO-08
6 photocoupler output channels (shared commons)
2 (independent) relay contact output channels (NC contact)

Fig 6.81 Digital Output Cards

PhotocouplerTD5

TD6

TD7

TD8

TD9

TD1
TD2
TD3
TD4

TD10
TD11

CH1

CH2

CH3

CH4

CH5

CH6

CH7

CH8

COM (0 V common)

Relay contact

DO-08 Digital Output Card

3CN

3CN

MxC
control
panel

Photocoupler

TD

NC

NC

NO

NO

1

2

3

4

5

6

CH1

CH2

Relay contact

+24 V

3CN

3CN

MxC
control
panel

DO-02C Digital Output Card

Advertising