Adjusting frequency gain using an analog input – Yaskawa Matrix Converter User Manual

Page 191

Advertising
background image

6

-26

„

Adjusting Analog Frequency Reference Using Parameters

The frequency reference is input from the control circuit terminals using analog voltage and current.

If using frequency reference terminal A1 as an input terminal, perform adjustments using parameters H3-02
and H3-03. If using multi-function analog input terminal A2 as a frequency reference terminal, perform
adjustments using H3-10 and H3-11.

Adjustment can be made using H3-06 and H3-07 when multi-function analog input terminal A3 is used as a
frequency reference terminal.

Fig 6.26 Terminals A1 and A2 Inputs

„

Adjusting Frequency Gain Using an Analog Input

When H3-09 or H3-05 is set to 1 (frequency gain), the frequency gain can be adjusted using the analog input
terminal A2 or A3.

Fig 6.27 Frequency Gain Adjustment (Terminal A2 Input)

H3-12

Analog Input Fil-
ter Time Constant

This parameter adjusts the filter on all 3 ana-
log inputs. Increase to add stability, decrease
to improve response.

0.00 to

2.00

0.03

s

No

A

A

A

Filter Avg Time

Parameter

Number

Name

Description

Setting

Range

Default

Change

during

Run

Control Methods

Display

V/f

Open

Loop

Vector

Flux

Vector

Frequency reference

Terminal A1, A3 input

Terminal A1 (A3)
input voltage

Frequency reference

Terminal A2 input

Terminal A2 input
voltage (current)

(H3-06)

(H3-07)

H3-03

H3-02

0 V

0 V (4 mA)

10 V (20 mA)

H3-11

H3-10

10 V

Frequency gain

Multi-function analog input
terminal A2 input level

100%

0 V (4 mA)

10 V (20 mA)

Advertising