Frequency Reference

6-

3

„

Inputting the Frequency Reference Using a Voltage Signal (Analog Setting)

When b1-01 is set to 1, the frequency reference can be entered from either control circuit terminal A1 (voltage
input) or control circuit terminal A2 (voltage or current input).

Inputting Master Speed Frequency Reference Only

When using a voltage signal to send the master speed frequency reference, use control circuit terminal A1.

Fig 6.2 Voltage Input for the Master Speed Frequency Reference

When using a current signal to provide the master speed frequency reference, use control circuit terminal A2.
Connect the 0 V lead to terminal A1, set H3-08 to 2 (allows current input for the multi-function analog input
terminal A2 signal level selection), and set H3-09 (Terminal A2 Function Selection) to 0 (add to terminal A1).

Fig 6.3 Current Input for Master Speed Frequency Reference

IMPORTANT

Set pin 2 of DIP switch S1 to the “on” position (towards I) when using current input to terminal A2 (pin 2 deter-
mines the voltage/current). Pin 2 of DIP switch S1 should be set to the “off” position (toward V) when inputting
a voltage to terminal A2. Set H3-08 to the correct setting for the type of input signal being used.

A1

A2

A3

Master speed frequency

reference

(voltage input)

Master speed frequency

reference

(current input)

Auxiliary speed frequency
reference 1

AC Analog common

2 k

Ω

+V Power supply: 15 V,
20 mA

MxC

A1

A2

A3

Master speed frequency
reference

(voltage input)

Master speed frequency
reference

(current input)

Auxiliary speed frequency
reference 1

AC Analog common

+V

4 to 20 mA input

DIP switch

S1

I

V

1
2

Power supply: 15 V,
20 mA

MxC