-24

„

The voltage tolerance between motor phases is insufficient.

When the motor is connected to the MxC output, a surge is generated between the MxC switching and the
motor coil. Normally the maximum surge voltage is three times the MxC's input power supply voltage (i.e.,
1,200 V for 400 V class). Be sure to use a motor with a voltage tolerance between motor phases that is greater
than the maximum surge voltage. In particular, when using a 400 V class MxC, use a special motor for invert-
ers.

„

Auto-Tuning has not been performed for Open Loop Vector Control.

Open Loop Vector Control will not operate the motor if Auto-Tuning has not yet been performed. Perform
Auto-Tuning, or calculate and set the motor parameters manually. Alternatively, change the Control Method
Selection to the V/f Control Method (A1-02 = 0).

‹

Noise is Produced from an AM Radio or when the MxC is Started

If noise is generated by MxC switching, then take the following action:

Change the MxC's Carrier Frequency Selection (C6-02) to lower the carrier frequency. This will help to
some extent by reducing the amount of internal switching.

Install an Input Noise Filter at the MxC's power supply input area.

Install an Output Noise Filter at the MxC's power supply output area.

Use metal tubing. Electric waves can be shielded by metal, so encase the MxC with metal (steel).

Ground the MxC and motor.

Separate main circuit wiring from control wiring.

‹

Ground Fault Interrupter Operates while the MxC is Running

The MxC performs internal switching, so there is a certain amount of leakage current. This may cause the
ground fault interrupter to operate and cut off the power supply. Change to a ground fault interrupter with a
high leakage detection level (i.e., a sensitivity current of 200 mA or greater per Unit, with an operating time of
0.1 s or more), or one that incorporates high frequency countermeasures (i.e., one designed for use with
inverter). It will also help to some extent to change the MxC’s Carrier Frequency Selection (C6-02) to lower
the carrier frequency. In addition, remember that the leakage current increases as the cable is lengthened.