Mxc protection, Reducing mxc overheating pre-alarm warning levels, Related parameters – Yaskawa Matrix Converter User Manual

Page 231

Advertising
background image

6

-66

MxC Protection

This section explains the functions for protecting the MxC.

‹

Reducing MxC Overheating Pre-Alarm Warning Levels

The MxC detects the temperature of the heatsink using the thermistor, and protects the MxC from overheating.
The MxC overheating pre-alarms will occur in units of 1

°

C.

The following overheating pre-alarm warnings are available: Stopping the MxC as error protection, and con-
tinuing operation with the alarm OH (Radiation fins overheating) on the digital operator flashing.

„

Related Parameters

* The default depends upon the MxC capacity. The value for a 200 V class MxC of 5.5 kW is given.

Parameter

Number

Name

Description

Setting

Range

Default

Change

during

Run

Control Methods

Display

V/f

Open

Loop

Vector

Flux

Vector

L8-02

Overheat Alarm
Level

When the cooling fin temperature exceeds the
value set in this parameter, an Overheat
Alarm (OH) will occur.

50 to

130

90

°C*

No

A

A

A

OH Pre-Alarm Lvl

L8-03

Overheat Pre-
Alarm Operation
Selection

Selects the MxC operation upon an OH pre-
alarm detection.
0: Decelerate to Stop
1: Coast to Stop
2: Fast-Stop
3: Alarm Only

0 to 3

3

No

A

A

A

OH Pre-Alarm Sel

Advertising