6

-36

‹

Hunting-Prevention Function

The Hunting-Prevention Function suppresses hunting when the motor is operating with a light load. This func-
tion can be set in V/f Control.

„

Related Parameters

Parameter

Number

Name

Description

Setting

Range

Default

Change

during

Run

Control Methods

Display

V/f

Open

Loop

Vector

Flux

Vector

n1-01

Hunting Preven-
tion Selection

0: Hunting-prevention function disabled
1: Hunting-prevention function enabled
The hunting-prevention function suppresses
hunting when the motor is operating with a
light load.
This function is enabled in V/f Control
method only.
If high response is to be given priority over
vibration suppression, disable the hunting-
prevention function.

0 or 1

1

No

A

No

No

Hunt Prev Select

n1-02

Hunting Preven-
tion Gain Setting

Set the hunting-prevention gain multiplication
factor.
Normally, there is no need to make this set-
ting.
Adjust this parameter as follows:
• If vibration occurs with light load, increase

the setting.

• If the motor stalls, reduce the setting.
If the setting is too large, the voltage will be
too suppressed and the motor may stall.

0.00 to

2.50

1.00

No

A

No

No

Hunt Prev Gain

n1-03

Hunting Preven-
tion Time Constant Set the hunting-prevention primary delay time

in units of ms.

0 to 500

10 ms

No

A

No

No

Hunt Prev Time