Related parameters – Yaskawa Matrix Converter User Manual

Page 249

Advertising
background image

6

-84

„

Related Parameters

Parameter

Number

Name

Description

Setting

Range

Default

Change

during

Run

Control Methods

Display

V/f

Open

Loop

Vector

Flux

Vector

b1-01

Frequency Refer-
ence Selection

Selects the frequency reference input source.
0: Operator - Digital preset speed U1-01 or

d1-01 to d1-17.

1: Terminals - Analog input terminal A1 (or

terminal A2 based on parameter H3-09).

2: Serial Com - Modbus RS-422/485 termi-

nals R+, R-, S+, and S-.

3: Option PCB - Option card connected on

2CN.

0 to 3

1

No

Q

Q

Q

Reference Source

b1-02

Run Command
Selection

Selects the Run Command input source.
0: Operator - RUN and STOP keys on digital

operator.

1: Terminals - Contact closure on terminals

S1 or S2.

2: Serial Com - Modbus RS-422/485 termi-

nals R+, R-, S+, and S-.

3: Option PCB - Option card connected on

2CN.

0 to 3

1

No

Q

Q

Q

Run Source

H5-01

MxC Node
Address

Set the MxC's station address.

0 to 20

*

1F

No

A

A

A

Serial Comm Adr

H5-02

Communication
Speed Selection

Set the baud rate for MEMOBUS communi-
cations of communications connection termi-
nals.
0: 1200 bps
1: 2400 bps
2: 4800 bps
3: 9600 bps
4: 19200 bps

0 to 4

3

No

A

A

A

Serial Baud Rate

H5-03

Communication
Parity Selection

Set the parity for MEMOBUS communica-
tions of CN6.
0: No parity
1: Even parity
2: Odd parity

0 to 2

0

No

A

A

A

Serial Com Sel

H5-04

Stopping Method
After Communica-
tion Error

Set the stopping method for communications
errors.
0: Deceleration to stop
1: Coast to stop
2: Emergency stop
3: Continue operation

0 to 3

3

No

A

A

A

Serial Fault Sel

H5-05

Communication
Fault Detection
Selection

Set whether or not a communications timeout
is to be detected as a communications error.
0: Do not detect.
1: Detect

0 or 1

1

No

A

A

A

Serial Flt Dtct

H5-06

MxC Transmit
Wait Time

Set the time from the MxC receiving data to
when the MxC starts to send.

5 to 65

5 ms

No

A

A

A

Transmit Wait-
TIM

H5-07

RTS Control
Selection

Select to enable or disable RTS control.
0: Disabled (RTS is always on)
1: Enabled (RTS turns on only when send-

ing)

0 or 1

1

No

A

A

A

RTS Control Sel