H2: multi-function contact outputs – Yaskawa Matrix Converter User Manual

Page 137

Advertising
background image

Parameter Tables

5-

37

„

H2: Multi-Function Contact Outputs

Multi-Function Contact Output Functions

Parameter

Number

Name

Description

Setting

Range

Default

Change

during

Run

Control

Methods

MEMO-

BUS

Register

Page

Display

V/f

Open

Loop

Vector

Flux

Vector

H2-01

Terminal M1 thru
M2 Function
Selection (Relay)

Multi-function contact output

0 to 37

0

No

A

A

A

40BH

-

Term M1-M2 Sel

H2-02

Terminal M3-M4
Function Selec-
tion (Relay)

Multi-function contact output 1

0 to 37

1

No

A

A

A

40CH

-

Term P1 Sel

H2-03

Terminal M5-M6
Function Selec-
tion (Relay)

Multi-function contact output 2

0 to 37

2

No

A

A

A

40DH

-

Term P2 Sel

H2-04

Terminal P3
Function Selec-
tion (Open Col-
lector)

Multi-function contact output 3

0 to 37

6

No

A

A

A

40EH

-

Term P3 Sel

H2-05

Terminal P4
Function Selec-
tion (Open Col-
lector)

Multi-function contact output 4

0 to 37

10

No

A

A

A

40FH

-

Term P4 Sel

Set

Value

Function

Control

Methods

Page

V/f

Open

Loop

Vector

Flux

Vector

0

During Run (ON: Run Command is on or voltage is being output)

Yes

Yes

Yes

6-77

1

Zero-speed

Yes

Yes

Yes

6-77

2

Frequency agree 1 (L4-02 used).

Yes

Yes

Yes

6-45

3

Desired frequency agree 1 (ON: Output frequency = ±L4-01, L4-02 used and during
frequency agree)

Yes

Yes

Yes

6-45

4

Frequency (FOUT) detection 1 (ON: +L4-01

≥ output frequency ≥ -L4-01, L4-02

used)

Yes

Yes

Yes

6-45

5

Frequency (FOUT) detection 2 (ON: Output frequency

≥ +L4-01 or output frequency

≤ -L4-01, L4-02 used)

Yes

Yes

Yes

6-45

6

MxC operation ready
READY: After initialization, no faults

Yes

Yes

Yes

-

7

During detection of power voltage fault (FDV, AUV, or UV)

Yes

Yes

Yes

-

8

During baseblock (ON: during baseblock)

Yes

Yes

Yes

-

9

Frequency reference selection (ON: Frequency reference from Operator)

Yes

Yes

Yes

-

A

Run Command selection status (ON: Run Command from Operator)

Yes

Yes

Yes

-

B

Overtorque/undertorque detection 1 NO (NO contact: Overtorque/undertorque detec-
tion at on)

Yes

Yes

Yes

6-49

C

Loss of frequency reference (Enabled when 1 is set for L4-05)

Yes

Yes

Yes

6-64